TURN OFF ALL POWER AT
CIRCUIT BREAKER/FUSE PANEL.
•
Read entire Installation Manual
before proceeding.
•
All wiring should comply with
local electrical codes and requires
a qualified electrician.
•
The total lighting load connected
to Stealth must not exceed 8 amps
(1000 watts incandescent or quartz,
500 watts fluorescent). To switch
more wattage an electrician can
install a relay.
• •
Line Carrier Remote Control
Systems such as X-10, Leviton or
Radio Shack are incompatible with
sensors and cause false activations.
• •
Do not install sensors on a
circuit that feeds motor loads
like kitchen appliances, HVAC
equipment, washer/dryer, or garage
door openers.
•
Sensor must be below and as far
as possible away from lights.
•
Sensor functions best when the
direction of expected movement
is across its detection pattern, not
towards the sensor.
•
Mount 6–12 feet high for
optimum range and detection.
STL110 floodlight kits come pre-
wired and assembled on the RAB
CU4 EZ plate, allowing for mounting
on round, rectangular or octagonal
surface or recessed boxes.
Cautions:
Mounting Plate:
Bar
Screws
Metal Mounting
Plate
CU4 EZ
Plate
Universal
Mounting Bar
Gasket
O-RingGasket
Insert
close-up
plug in
unused
hole
Finishing
Cap
1