background image

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install 

and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]

INSTRUCTIONS

 

LOS800 BAY SENSOR

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

  

RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is 
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON 
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 

WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. 

PIR Sensor , with IR remote capability

SPECIFICATIONS AND FEATURES

OPTICAL

• Indoor use only
• Operating Temperature: 32°F to 158°F (0°C to 70°C)
• Operating Humidity: 5% to 95%, noncondensing
• Line voltage for direct connection to load
• 120, 277, 347V, 60Hz or 230V, single phase, 50Hz operation
• Power consumption: 0.2W
• Adjustable time delay and sensitivity
• Adjustable hold-off daylighting level
• Weight: 6.4 oz (181 g)
• UL listed snap-in mounting hardware
• Easy mounting using knockout at end of fluorescent high

bay luminaire

• Flexible mounting options
• UL listed

• Lens (attached) designed for mounting heights from 15

to 40 feet

• Snap-on rotatable mask for aisleway applications (included)
• Covers a 100-foot diameter area when mounted at a height

of 40 feet

FACTORY DEFAULTS

• Time Delay: 15 minutes
• Sensitivity: Max
• Light Level: 300 footcandles

1.64in 

41.8mm

2.76in 

70mm

4.28in 

108.7mm

3.23in 

82mm

2.36in 

60mm

.66in 

16.7mm

1.09in 

27.7mm

Fig. 1

Содержание LOS800

Страница 1: ...n power is OFF before installing or maintaining fixture No user serviceable parts inside PIR Sensor with IR remote capability SPECIFICATIONS AND FEATURES OPTICAL Indoor use only Operating Temperature 32 F to 158 F 0 C to 70 C Operating Humidity 5 to 95 noncondensing Line voltage for direct connection to load 120 277 347V 60Hz or 230V single phase 50Hz operation Power consumption 0 2W Adjustable ti...

Страница 2: ...eting rablighting com INSTRUCTIONS HIGH LOW BAY PASSIVE INFRARED OCCUPANCY AND DAYLIGHT SENSOR LENS MASKING AND COVERAGE Lens Dimensions Top coverage pattern Side coverage pattern Top coverage pattern with mask Side coverage pattern with mask Shown with snap on rotatable mask for aisleway coverage included with sensor 50 25 0 25 50 0 50 25 25 50 100 50 25 0 25 50 0 50 25 25 50 100 0 10 10 20 20 30...

Страница 3: ... any necessary mounting accessories and attach them to the sensor making sure that the flying leads from the power module are accessible 6 Connect the line voltage and load wires to the sensor leads as shown in the Wiring Diagram see Figure 4 Do not allow bare wire to show Make sure all connections are secure 7 Restore power from the circuit breaker SETTING TIME DELAY Trimpot 1 Adjust the trimpot ...

Страница 4: ...n is detected and the time delay has not expired If the load is turned OFF manually the sensor holds the load OFF for as long as motion is detected and then for an additional 5 minutes of no motion detection The next time the sensor detects occupancy and the ambient light is lower than the established light level the sensor automatically turns ON the load Test Mode To place the unit in a 10 minute...

Страница 5: ...here is no motion detected after the first 30 seconds If occupancy continues beyond the first 30 seconds the established time delay applies Default setting is Disabled Visual Alert When enabled Visual Alert turns the load OFF for 1 second to warn any occupants of impending shutoff 1 minute before the time delay countdown expires Default setting is Disabled Occupancy mode When Occupancy mode is dis...

Отзывы: