background image

WPLED   10W INSTALLATION INSTRUCTIONS

Thank you for buying RAB lighting fi xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: [email protected]

®

Junction Box

 

Surface Mount

 

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

.

Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required 

for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON 

FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. 

WARNING: Make certain power is OFF before installing or maintaining fi xture. No user serviceable parts inside.

CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened 

fi rmly. Apply weatherproof silicone sealant around the edge of the Back Box and/or Junction Box. This is especially 

important with an uneven wall surface. Silicone all plugs and unused conduit entries.

JUNCTION BOX MOUNT FOR 

CONDUIT

For use on applications where conduit wiring is necessary.

1. 

Loosen and remove (3)

 Lens Screws

. Remove 

Door

.

2. 

Loosen and remove (2) 

Housing Screws

. Remove 

Housing

 from 

Back Box

. Keep 

Housing Gasket

 intact 

for re-assembly.

3. 

Secure 

Back Box

 to the mounting surface using 

hardware appropriate for that mounting surface.

4. 

Wire the fi xture using UL listed wire connectors 

according to NEC and local codes. Apply sealant to all 

unused conduit entry points.

5. 

Place 

Gasket

 between 

Back Box

 and 

Housing

.  

Re-mount 

Housing

 to 

Back Box

. Check 

Housing

 

Gasket

 

seal all around the 

Back Box

6. 

Re-mount 

Door

 to 

Housing

. Tighten (3) 

Lens Screws. 

Check door gasket (not shown) seal.

7. 

Fixture can be mounted as an uplight.

Lens Screws

SURFACE MOUNT FOR RECESSED 

BOX

For use with recessed junction box and wiring.

1. 

Use supplied 

Crossbar

. Mount 

Crossbar

 to 

Recessed 

Junction Box

 with (2) screws.

2. 

Place 

Gasket

 on back of the fi xture. 

Gasket

 should create 

seal against mounting surface.

3. 

Wire fi xture to supply wires in 

Recessed Box

 according 

to wiring section.

4. 

Use 1/4 x 20 stainless steel 

Mounting Screw

 to attach 

fi xture to 

Crossbar

. Tighten 

Mounting Screw

.

5. 

Cover screw with 

Cap, 

provided.

6. 

Fixture can be mounted as an uplight.

Crossbar

Gasket

Mounting 

Screw

Cap

Back Box

Housing 

Gasket

Housing

Door

Housing 

Screws

Recessed Junction Box 

(not provided)