REMODELER & NEW CONSTRUCTION TRIM  

2IN 10W ROUND & SQUARE INSTRUCTIONS

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-RAB-1000 or email: [email protected]

REMODELER MOUNTING 

For round ceiling cut out 2-3/8” dia. For square ceiling use 

the 2-3/8” sq cut out template from packaging material.
1.  Install 

Ceiling Collar

 into opening. Secure Ceiling Collar 

by pushing fingertabs down tightly over ceiling. Fig. (3) 

Note: Ceiling Collar is intended for 5/8”-3/4” sheet rock 

ceilings. For 1/2” ceiling applications, use 1/8” shim to secure 

trim module. 

2.  Loosen the 

Junction Box Screw

 and open the 

Junction 

Box 

(Fig.2). Attach 

Supply Wires

 into 

Junction Box

 and 

connect to the fixture. See wiring section for details.

3.  Push up and slide the 

Junction Box

 section into the 

Ceiling Collar

. Be sure the 

Spring Clips 

are snapped in

 

and

 Trim Ring 

is flush and secure. 

Ceiling 

Fig: 3

Remodeler Unit

Fig: 4

Ceiling Collar

5/8” TYP 
3/4”MAX

TROUBLESHOOTING 

1.  Check that the line voltage at the fixture is correct. Refer 

to wiring directions.

2.  Is the fixture grounded properly?

CLEANING & MAINTENANCE 

CAUTION: Be sure fixture temperature is cool enough to 

touch. Do not clean or maintain while fixture is energized.

1.  Do not open fixture to clean the LED. Do not touch  

the LED.

2.  Do not touch reflector, lens or trim cone.
3.  Do not clean any fixture surface with wood base cleaning 

material such as paper towels or tissues. 

WIRING

 

RISK OF FIRE

.  Universal voltage driver permits operation 

at 120V thru 277V, 50 or 60 Hz. Drop down supply wires 

must be at least 9” long to allow fixture removal. For Non-

Dimming (on/off), Electronic Low Voltage (ELV) and Triac 

Dimming follow the wiring directions in Fig. 6. For 0-10V 

dimming, Fig. 7.

1.  Connect GROUND wire from fixture to supply ground.
2.  Connect black fixture lead to the (+) LINE supply lead.
3.  Connect white fixture lead to the (-) COMMON supply lead.

Ceiling Collar

use wood 

Shim (if 

necessary)

WALLWASH MOUNTING 

1.  For the Wallwash Model, orient the fixture such that 

the 

Lens such that the thin section

 is aimed in correct 

orientation. 

2.  If necessary, rotate of the wall wash lens to orient in 

certain direction.

Fig: 5

This side away 

from wall

Wall Wash lens

Fig: 7

Fig: 6

Отзывы: