▣ Cautions during Use

1.  Follow instructions in 'Cautions during Use'. Otherwise, it may 

cause unexpected accidents.

2.  Do not install where strong magnetic or electric field exist. 

Otherwise, the resolution may be adversely affected. 

3.  Wire as short as possible and keep away from high voltage 

lines or power lines, to prevent surge and inductive noise.

4.  For the optimized performance, it is recommended to 

measure after 30 minute from supplying power.

5.  When detecting with the maximum sensitivity, an error may 

occur depending on each characteristic deviation.

6. This unit may be used in the following environments.

①Indoors/Outdoors (in the environment condition rated in

'Specifications')

②Altitude max. 2,000m
③Pollution degree 2
④Installation category II 

Power indicator (POWER):

 Green, Displays power supply.

Status Reason

Solution

On

Power is 

supplied.

-

Off

Power is not 

supplied.

After checking the connection 

between communication converter 

and amplifier unit correctly, 

reconnect the device.

Communication output indicator (TX):

  

Green, Displays communication output status from  

communication converter to external device.

Status Reason

Solution

Flashing Signal is 

outputting.

-

Off

Signal is not 

outputting.

-

Communication input indicator (RX):

  

Green, Displays communication input status from 

communication converter to external device.

Status Reason

Solution

Flashing Signal is 

inputting.

-

Off

Signal is not 

inputting.

-

Communication error indicator (ERROR):

  

Red, Displays the communication status of communication 

converter.

Status Reason

Solution

On

Connection is 

bad between 

communication 

converter and 

amplifier unit.

After checking the connection 

between communication converter 

and amplifier unit correctly, 

reconnect the device.

Flashing

Communication 

is bad between 

communication 

converter and 

amplifier unit.

After checking the connection 

between communication converter 

and amplifier unit correctly, 

reconnect the device.

Apply noise prevention to 

communication converter and 

amplifier unit.

Off

Operation is 

normal.

-

POWER TX

RX ERROR

▣ Status Indicators

ООО “РусАвтоматизация”

454010 г. Челябинск, ул. Гагарина 5, оф. 507

тел. 8-800-775-09-57 (звонок бесплатный), +7(351)799-54-26, тел./факс +7(351)211-64-57

[email protected];

русавтоматизация.рф;

www.rusautomation.ru

Содержание BD-C Series

Страница 1: ...load manuals Proper Usage Before using the communication converter unit depending on the usage environment keep following items handy Visit our web site www autonics com to download atDisplacement program manual SCM 38I RS232C RS485 Driver Instruction manual SCM US48I USB RS485 Driver Instruction manual SCM WF48 Wi Fi USB RS485 Driver Instruction manual BD Series manual Dedicated Device Management...

Страница 2: ... weight The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment BD C Series Communication Converter Model BD CRS Power supply 1 Power consumption Max 2 3W Communication function RS 232C RS 485 Communication speed 9600 19200 38400 115200bps default Indication 4 LED status indicators Function Real time monitoring Executes every BD Series feature and ...

Страница 3: ...ly Communication output indicator TX Green Displays communication output status from communication converter to external device Communication input indicator RX Green Displays communication input status from communication converter to external device Communication error indicator ERROR Red Displays the communication status of communication converter 4 Communication Setting Switch Sets communicatio...

Страница 4: ...SUB 9 pin cable 1 6 2 3 4 5 7 8 9 1 6 2 3 4 5 7 8 9 RS485 communication Pin Name Description 1 A RS485 signal 2 B RS485 signal Communication pin Terminating switch Set the switch to RT when the communication converter is connected to the terminal of RS485 communication connection and set to OFF when it is in the middle of the communication connection 1 A B 2 Application of system organization Comp...

Страница 5: ...ommunication converter It is calculated in binary according to the ON OFF status of each switch Switch No Switch3 Switch4 Switch5 Switch6 Switch7 Address Binary digit OFF 0 ON 1 2 4 2 3 2 2 2 1 2 0 Address Switch 3 2 4 Switch 4 2 3 Switch 5 2 2 Switch 6 2 1 Switch 7 2 0 1 Address 1 OFF OFF OFF OFF OFF 1 0 2 4 0 2 3 0 2 2 0 2 1 0 2 0 1 Address 2 OFF OFF OFF OFF ON 2 0 2 4 0 2 3 0 2 2 0 2 1 1 2 0 1 ...

Страница 6: ...necting amplifier unit Mount on DIN rail Do not supply the power when adding amplifier unit Supply power to each connected amplifier unit at the same time Up to 8 amplifier units can be connected and only 1 calculation function can be performed per 1 group of mutually connected amplifiers When the calculation function is activated the setting values SV of the slave units are disable and the mutual...

Страница 7: ...TX Green Displays communication output status from communication converter to external device Status Reason Solution Flashing Signal is outputting Off Signal is not outputting Communication input indicator RX Green Displays communication input status from communication converter to external device Status Reason Solution Flashing Signal is inputting Off Signal is not inputting Communication error i...

Отзывы: