background image

Laser Displacement Sensor Communication Converter

-|Transparent setting 

guide|-

▣ Product Composition

Sensor 

Head

• Measuring displacement of object

• Using power from the amplifier unit

Amplifier 

Unit

• Setting parameter and 

communication input/output

• Connecting 1 sensor per 1 unit

• Max. 8 units mutual connection 

Communication

Converter

• Supporting communication function

• Max. 8 units mutual connection 

• Using power from the amplifier unit

Extension

Cable

• Extending connection distance 

between sensor head and amplifier unit

Specifications

※1: Using power from the amplifier unit. To use BD-C Series communication converter, the amplifier unit needs 12-30VDCᜡ 

power supply.

※2: This weight is with packaging and the weight in parentheses is only unit weight.

※The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.

BD-C Series Communication Converter

Model

BD-CRS

Power supply

※1

-

Power consumption

Max. 2.3W

Communication function

RS-232C, RS-485

Communication speed

9600, 19200, 38400, 115200bps (default)

Indication

4 LED status indicators

Function

• Real-time monitoring

•  Executes every BD-Series feature and sets parameter by external device (Master)

Envir

onment

Ambient 

temperature

-10 to 50℃, Storage: -15 to 60℃

Ambient humidity

Under 85%RH, Storage: under 85%RH

Vibration

1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours

Shock

300m/s

(approx. 50G) in each X, Y, Z direction for 3 times

Protection structure

IP40 (IEC Standards) 

Material

Case: Polycarbonate

Accessory

Side connector, Connector for RS485

Sold separately

Communication converter (SCM-38I, SCM-US48I, SCM-WF48)

Approval
Weight

※2

Approx. 91g (approx. 49g)

Содержание BD-C Series

Страница 1: ...load manuals Proper Usage Before using the communication converter unit depending on the usage environment keep following items handy Visit our web site www autonics com to download atDisplacement program manual SCM 38I RS232C RS485 Driver Instruction manual SCM US48I USB RS485 Driver Instruction manual SCM WF48 Wi Fi USB RS485 Driver Instruction manual BD Series manual Dedicated Device Management...

Страница 2: ... weight The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment BD C Series Communication Converter Model BD CRS Power supply 1 Power consumption Max 2 3W Communication function RS 232C RS 485 Communication speed 9600 19200 38400 115200bps default Indication 4 LED status indicators Function Real time monitoring Executes every BD Series feature and ...

Страница 3: ...ly Communication output indicator TX Green Displays communication output status from communication converter to external device Communication input indicator RX Green Displays communication input status from communication converter to external device Communication error indicator ERROR Red Displays the communication status of communication converter 4 Communication Setting Switch Sets communicatio...

Страница 4: ...SUB 9 pin cable 1 6 2 3 4 5 7 8 9 1 6 2 3 4 5 7 8 9 RS485 communication Pin Name Description 1 A RS485 signal 2 B RS485 signal Communication pin Terminating switch Set the switch to RT when the communication converter is connected to the terminal of RS485 communication connection and set to OFF when it is in the middle of the communication connection 1 A B 2 Application of system organization Comp...

Страница 5: ...ommunication converter It is calculated in binary according to the ON OFF status of each switch Switch No Switch3 Switch4 Switch5 Switch6 Switch7 Address Binary digit OFF 0 ON 1 2 4 2 3 2 2 2 1 2 0 Address Switch 3 2 4 Switch 4 2 3 Switch 5 2 2 Switch 6 2 1 Switch 7 2 0 1 Address 1 OFF OFF OFF OFF OFF 1 0 2 4 0 2 3 0 2 2 0 2 1 0 2 0 1 Address 2 OFF OFF OFF OFF ON 2 0 2 4 0 2 3 0 2 2 0 2 1 1 2 0 1 ...

Страница 6: ...necting amplifier unit Mount on DIN rail Do not supply the power when adding amplifier unit Supply power to each connected amplifier unit at the same time Up to 8 amplifier units can be connected and only 1 calculation function can be performed per 1 group of mutually connected amplifiers When the calculation function is activated the setting values SV of the slave units are disable and the mutual...

Страница 7: ...TX Green Displays communication output status from communication converter to external device Status Reason Solution Flashing Signal is outputting Off Signal is not outputting Communication input indicator RX Green Displays communication input status from communication converter to external device Status Reason Solution Flashing Signal is inputting Off Signal is not inputting Communication error i...