How to control a D.C.voltage superior to 5V
Connect to DB25 marked as BALANCED ANALOG INPUT on the PIN described in
the table
Pin number
Meant
Adj. Trimmer
2 (+), 14 (
−
)
Analogic balanced input n°1
RV1
3 (+), 16 (
−
)
Analogic balanced input n°2
RV2
5 (+), 17 (
−
)
Analogic balanced input n°3
RV3
6 (+), 19 (
−
)
Analogic balanced input n°4
RV4
8 (+), 20 (
−
)
Analogic balanced input n°5
RV5
9 (+), 22 (
−
)
Analogic balanced input n°6
RV6
11 (+), 23 (
−
)
Analogic balanced input n°7
RV7
12 (+), 25 (
−
)
Analogic balanced input n°8
RV8
1, 4, 7, 10, 13, 15,
18, 21, 24
Massa
Obtain the maximum of the voltage and regulate the correspondent trimmer in order
to obtain the visualization, on the remote control software, the voltage of 5V. See the
software manual to set up correctly the database necessary to have an immediate
visualization of the parameter in the right unit of measure.
3.3.2
How to control a voltage inferior to 5V
Connect to DB25 marked as DIGITAL/ANALOG INPUT on the PIN described in the
table:
Pin number
Meant
Jumper su JP4
2
Digital/analogic unbalanced input n°1
pos. 1
15
Digital/analogic unbalanced input n°2
pos. 2
3
Digital/analogic unbalanced input n°3
pos. 3
16
Digital/analogic unbalanced input n°4
pos. 4
4
Digital/analogic unbalanced input n°5
pos. 5
17
Digital/analogic unbalanced input n°6
pos. 6
5
Digital/analogic unbalanced input n°7
pos. 7
18
Digital/analogic unbalanced input n°8
pos. 8
21
Digital/analogic unbalanced input n°9
pos. 9
9
Digital/analogic unbalanced input n°10
pos. 10
22
Digital/analogic unbalanced input n°11
pos. 11
10
Digital/analogic unbalanced input n°12
pos. 12
23
Digital/analogic unbalanced input n°13
pos. 13
11
Digital/analogic unbalanced input n°14
pos. 14
24
Digital/analogic unbalanced input n°15
pos. 15
12
Digital/analogic unbalanced input n°16
pos. 16
1, 6, 7, 8, 13, 14,
19, 20, 25
GND
Obtain the visualization, on the remote control software, of the parameter. See the
software manual to set up correctly the database necessary to have an immediate
visualization of the parameter in the right unit of measure.
Содержание TLC300
Страница 1: ...Manufactured by Italy TLC300 User Manual...
Страница 4: ...TLC300 ii User Manual Rev 1 0 07 04 03 This page was intentionally left blank...
Страница 6: ...TLC300 2 42 User Manual Rev 1 0 07 04 03 This page was intentionally left blank...
Страница 20: ...TLC300 16 42 User Manual Rev 1 0 07 04 03 This page was intentionally left blank...
Страница 30: ...TLC300 26 42 User Manual Rev 1 0 07 04 03 This page was intentionally left blank...
Страница 34: ...TLC300 30 42 User Manual Rev 1 0 07 04 03 This page was intentionally left blank...
Страница 40: ...TLC300 36 42 User Manual Rev 1 0 07 04 03 This page was intentionally left blank...
Страница 80: ...SCM TLC 32 50 User Manual Rev 1 0 17 01 03 This page was intentionally left blank...
Страница 90: ...SCM TLC 42 50 User Manual Rev 1 0 17 01 03 This page was intentionally left blank...
Страница 96: ...SCM TLC 48 50 User Manual Rev 1 0 17 01 03 This page was intentionally left blank...
Страница 98: ...SCM TLC 50 50 User Manual Rev 1 0 17 01 03 This page was intentionally left blank...
Страница 100: ...TLC300 CSTLSCCPU002 1 4 Appendice Tecnica Rev 1 1 27 05 03...