TEX52TFT
15
/ 42
User Manual
Rev. 1.0 - 12/07/20
ELETTRONICA
5.1.5 Initial start-up and setting of operation
For initial start-up, follow the procedure below.
Note: RF EXPOSURE SAFETY DISTANCE (only for FCC & IC)
RF Exposure Limits for the United States of America, according to FCC regulation:
Set the output power of the unit to maximum to ensure the exposure limits stated
in this document. The gain of the antenna used with this device must be 0 dBi or
less and all people must maintain a minimum safety distance of
638.41 cm
.
Radio Frequency Exposure Limits for Canada, according to IC regulation: set the
output power of the unit to maximum to ensure the exposure limits stated in this
document. The gain of the antenna used with this device must be 0 dBi or less
and all people must maintain a minimum safety distance of
785.90 cm
.
5.1.5.1 Power on
After making the connections described above, turn on the device at the power
switch on the front.
The default screen appears on the display and when the
PLL
is locked to the
working frequency, the
LOCK
LED lights up.
5.1.5.2 Setting the working frequency
Access the
FRQ
menu and use the touchscreen or keys
and to adjust the
working frequency of the equipment.
Press
ENTER
to confirm and wait for the
LOCK
LED to come on again.
5.1.5.3 Enabling the RF output
If the power readings are zero, enable the RF output:
• Access the
PWR
menu and
check that the output power level is different
from 0%.
• Check the status of the output power,
Power
. Set the status to
ON
and
make
sure that the
ON
LED comes on.
5.1.5.4 Checking the output power level
IMPORTANT:
The equipment has automatic level control (ALC) and the output
power is delivered based on the level adjusted by the user and the actual
working conditions, such as temperature, reflected power and other parameters.
Please read the section on RF power feedback.