Rear Panel
[1] INTERLOCK/ALARMS
BNC connectors to inhibit an exteral device, as an exciter. In case of
fault, the inner connector is shorted to ground.
[2] R.F. MONITOR
BNC RF monitor output. The output level is -60 dB below the power
output in the band 87.5-108 MHz.
[3] RS232
DB9 conector to link the amplifier with external devices.
[4] I
2
C
DB9 connector for IIC bus networking.
[5] OUTPUT 1 to 5
Power Splitter Outputs (N-type connector) to drive Power Amplifiers.
[6] INPUT
Exciter’s R.F. Input connector (N-type).
[7] TELEMETRY
DB25 telemetry connector.
[8] 24 V
External 24 V dc power supply input for CPU backup power supply.
[9] FOLD-BACK
BNC connector for the fold-back connection..
[10] FUSE
Protection Fuse for Auxiliary Out A.C. Power Line.
[11] VOLTAGE CHANGER &
A.C. LINE FUSE
Fuse block and Line Voltage Selector. Use a small screwdriver to change
the fuse or line voltage. Rotate the block and position it for desired voltage.
[12] UNBAL F.BACK ADJ.
Trimmer for Unbal Fold Back adjustment.
[13] AUX. OUT A.C. LINE
Auxiliary Out A.C. Power Line for the combiner.
[14] INPUT 1 to 5
Power Combiner Inputs (N-type) from the Power Amplifiers.
[15] HEAT SINK
Heat Sink for the R.F. Output Combiner.
Содержание HC5
Страница 1: ...Manufactured by Italy HC5 User Manual LCD version...
Страница 4: ...HC5 ii User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...
Страница 6: ...HC5 2 34 User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...
Страница 22: ...HC5 18 34 User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...
Страница 28: ...HC5 24 34 User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...