Two of the settable thresholds are related to the RF emitted power (Power Good),
while the third is connected to the amount of reflected power (Reflected Warning).
The thresholds are expressed as percentage of full-scale value of the relevant
quantity.
The full scakle values for the HC5 are the following:
•
Forward power
5000W
•
Reflected power 500W
To change the values of the thresholds, execute the following procedure:
•
Select the line to modify (UP and DOWN buttons)
•
Push the ENTER button
•
Modify the value of the threshold (UP and DOWN buttons)
•
Push the ENTER button to confirm
The following figure shows an example of configuration for this menu.
In questo esempio, le soglie degli allarmi sono:
•
PwrGd 1
4000W
(80% X 5000W)
•
PwrGd2
2500W
(50% X 5000W)
•
RflWar
350W
(70% X 500W)
•
SwrWar
475W
(95% X 500W)
5.3.5
Alarms Menu (Alm)
This screen gives to the user information regarding the status of the protection
system included in the hybrid coupler.
It is constituted by a certain number of lines, each containing the name of a variable
controlled by the system and the kind of intervention that is undertaken by the
system in case the parameter surpasses its limit.
The latter can be of the kind: X - (Y), Wait, or Dis. (Disabled).
The aspect of this multi-line screen is the following (only two lines at a time are
visible, use the UP and DOWN buttons to scroll):
Содержание HC5
Страница 1: ...Manufactured by Italy HC5 User Manual LCD version...
Страница 4: ...HC5 ii User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...
Страница 6: ...HC5 2 34 User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...
Страница 22: ...HC5 18 34 User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...
Страница 28: ...HC5 24 34 User Manual Rev 1 0L 11 02 02 This page was intentionally left blank...