DISCOVERY
18 / 44
User Manual
Rev. 2.1 - 27/11/03
When it is allowed while performing changes in Detect, Priority or Var., it is not
possible to exit the Manual function until the change is ended or aborted.
It is also possible to proceed with the control operation from the PC. To do it, after
connecting it to the serial port, enter the order: Micro|Read, to read its configuration
from control, followed by the order Micro|Test, which will display on a panel the
status of inputs and outputs. For channels anyway enabled, the voltage value is
also displayed on the left and right channel, also value db is visualised.
The view is updated every two seconds.
6.3
Trasferimento dati da P.C. alla CPU-SWITCH
To transfer operative parameters to CPU-SWITCH, previously made or loaded
from file, it is required to follow the procedure below.
1) Using the manager file or my computer, click on icon Switch to run the program.
2) Make or load from files the desired parameters.
3) Switch the CPU-SWITCH off.
4) Press key <Ok> on the CPU-SWITCH. Switch it on keeping pressed the key
and release the button after one second approximately. If the procedure has
been complied with, the display will view the word Configuration; at this point,
operate as follows:
Select the Micro field or the corresponding icon.
Select item Micro Write Configuration.
By this last operation, data has been transferred from the PC memory to the E²prom
memory of CPU-SWITCH; if the operation has been correctly performed, the
Transfer Completed message will be displayed.
To start the machine, after configuring the processor, switch it off and again on.
During the operation, if icon Micro|Write Configuration is pressed by chance, the
Eeprom write protected message or, if the control has been configured as
unchangeable, the Program Running message will be displayed. Anyway, to change
parameters, the procedure set forth in point [3] needs to be repeated.
Only to change the Heading, it is needed to make a new one with the
Configuration|Title command; subsequently, repeat points [3] and [4] above and
at this point:
Select item Micro|Write Title in field Micro.
N.B.: When the CPU-SWITCH is started for the first time, being the programming
parameters available, it automatically preset to receive data. No other operation is
allowed.
Содержание discovery
Страница 1: ...Manufactured by Italy DISCOVERY User Manual...
Страница 4: ...DISCOVERY ii User Manual Rev 2 1 27 11 03 This page was intentionally left blank...
Страница 6: ...DISCOVERY 2 44 User Manual Rev 2 1 27 11 03 This page was intentionally left blank...
Страница 12: ...DISCOVERY 8 44 User Manual Rev 2 1 27 11 03 This page was intentionally left blank...
Страница 20: ...DISCOVERY 16 44 User Manual Rev 2 1 27 11 03 This page was intentionally left blank...
Страница 24: ...DISCOVERY 20 44 User Manual Rev 2 1 27 11 03 This page was intentionally left blank...
Страница 30: ...DISCOVERY 26 44 User Manual Rev 2 1 27 11 03 This page was intentionally left blank...
Страница 32: ...DISCOVERY 28 44 User Manual Rev 2 1 27 11 03 The figure 9 2 shown the exchange logics Figure 9 2...
Страница 34: ...DISCOVERY 30 44 User Manual Rev 2 1 27 11 03 This page was intentionally left blank...
Страница 45: ...DISCOVERY 41 44 User Manual Rev 2 1 27 11 03 11 References 11 1 Meant of the LED...
Страница 48: ...DISCOVERY 44 44 User Manual Rev 2 1 27 11 03 This page was intentionally left blank...