background image

Speed-Timer 3000 and 3000 (RF) Operating Instructions.

Speed-Timer 3000 and 3000 (RF): Install a 9 volt Alkaline Battery in the battery

compartment of the Speed-Timer 3000 and 3000 (RF)

Range Officer Mode: (instant start signal)

Press and hold down the START/RESET key for three seconds or longer (“0 sec will appear 

on the screen) then release the START/RESET  key to initiate the Record Mode for an instant 

start. Then read the number of shots fired, the elapsed time, and the split time between the last 

two shots fired

Shot Time: Practice Mode (2.5 to 5.0 second Random Delay Start Signal) Press

and hold down the START/RESET key from one to three seconds (“dEL” will appear on the 

screen) then release the START/RESET  key to initiate the Record Mode with 2.5 to 5.0 

second Random delay start. Wait for the audible start signal and begin shooting. Then read 

the number of shots fired, the elapsed time, and the split time between the last two shots fired.

Review Mode:

To review all shots fired (in order), press and release (less than one second) the

START/RESET  key and start cycling through the shots fired. Press and release (less than one 

second) for all remaining shots.

Last 8 Shot Stings  

Enter the Review Mode above, push the up or down arrow to review the last shot fired in the 

last 8 Strings. Push the START/RESET Key one time to exit Last 8 Shot Strings and return to 

the Review Mode and display all shots fired in the unsaved string.

NOTE the strings do not get saved in memory, unless you have started a new string. The 

current string will still be on the screen with all shots fired and the last eight starts will be 

stored in memory.

Turning the Timer Off

Enter the Review Mode as above and the Timer will automatically shut off in approximately ten  

minutes in the Review Mode or while in the Review Mode you may press the MODE key to 

shut the timer off. You will not lose the shot times in memory. Press and release the 

START/RESET key at any time for less than one second to reactivate. Removing or changing 

the battery will not erase shot times stored.

Range Officer Walk Through , PAR, Sensitivity Setting or Battery Test: Setting “r0F” Time ,“P” 

Time, Sensitivity Setting “Pot” and Battery Test “bAt”

While in Shot Time, the MODE key is deactivated preventing any accidental interruption in 

recording shots fired. The Setting “r0F” Time ,“P” Time, Sensitivity Setting “Pot” and Battery 

Test “bAt” “can only be activated by pressing and releasing the MODE  key two times from the 

Review Mode or if the timer is off, one time from a blank screen.

Press and release the MODE key for 3 to 4 seconds to toggle to “r0F” Time ,“P” Time, 

Sensitivity Setting “Pot” and Battery Test “bAt” . 

Stop at the program required.

RO Officer Walk Through; Choice a walk through time In “r0F”, move the clock in full minutes 

from 1-10 minutes, by using the up or down arrow keys to set the desired time. (this time will 

remain in memory until it is changed using the above method) Push and release the 

“START/RESET ” to start the walk through timing. Note: a single signal will sound to start the 

count down, a double signal will sound to warn of one minute remaining in the walk through 

and three signals to warn that the walk through time has expired. The Timer will then enter 

Record Mode automatically at the end of the set time or if for any reason you stop the clock.

PAR Time: Setting PAR Time In “P” Mode (see above). The screen will display OFF or a time 

previous set. Using the up arrow key move the clock to the desired time.(holding down a arrow 

key will cause the time to cycle at a faster rate) Press the START/RESET key to exit PAR 

setting and save your selection. The PAR time is set and may be operated in either random 

delay start or instant start with full review capabilities. Note: The letter P will be present to 

indicate PAR time is active and set when starting the Timer in Shot Time. PAR range .1 second 

to 10 Minutes (600 seconds) in 10 th of a second. Pushing and holding in the UP or Down key 

will allow the time to rapidly advance. At the end of the set PAR time the buzzer will sound and 

show the last shot fired and number of shots fired before the buzzer, review your shots by 

using the up and down arrows. Any shot fired after the during or after the  buzzer is considered 

overtime and does not display.

To exit PAR time and return to Shot Time.

From the Review Mode, press and release the MODE key to exit and press and release the 

MODE Key for 3 Seconds to enter setup. Toggle to “PAR” Time, arrow down until the screen 

reads OFF. Press the START/RESET  key to exit.

To exit RO Officer Walk Through: Toggle through by pressing the MODE Key the “r0F” 

Time ,“P” Time, Sensitivity Setting “Pot” and Battery Test “bAt” to “P” Time. Press the “MODE” 

key to exit and turn the Speed-timer 3000 off.

Sensitivity

The Speed-Timer 3000 is factory set for a sensitivity to handle the majority of Firearms indoors 

and out. It is set to pickup shots from approximately 20 Feet (6 Meters) from the Timer. Under 

normal circumstances there is no need to change these setting, however this Timer can be 

modified to suit a particular location or application if necessary.

Sensitivity Adjustment

While in Shot Time, the MODE key is deactivated preventing any accidental interruption in 

recording shots fired. The Setting “r0F” Time ,“P” Time, Sensitivity Setting “Pot” and Battery Test 

“bAt” “can only be activated by pressing and releasing the MODE  key two times from the Review 

Mode or if the timer is off, by pressing and releasing the MODE key one time from a blank screen.

With the Screen blank, press, hold and release the MODE key for 3-4 Seconds and release and 

toggle to Setting “r0F” Time ,“P” Time, Sensitivity Setting “Pot” and Battery Test “bAt”  setup 

screens. Stop at Sensitivity Setting “Pot”.

To change the sensitivity setting use the up or down arrow to choice between 0 and 63 as a 

setting to suit your application. Test the setting by firing a few rounds so the you can test your 

setting, you will note that as you fire the number in the right corner of the screen will increase to 

indicate that the shots have been tested. There is no need to go to Shot Time Mode for this 

adjustment. 

When you are satisfied with the results, simply us the arrow keeps to exit the 

setup program.

 

Factory Setting is 32.

Battery Test

While in Shot Time, the MODE key is deactivated preventing any accidental

interruption in recording shots fired. The Setting “r0F” Time ,“P” Time, Sensitivity Setting “Pot” and 

Battery Test “bAt” “can only be activated by pressing and releasing the MODE  key two times from 

the Review Mode or if the timer is off, one time from a blank screen.

Simply index through  r0F” Time ,“P” Time, Sensitivity Setting “Pot” to Battery Test “bAt, and read 

the current health of your battery. Example 9.0 volts. Press the Mode to Exit.

Battery Low Indicator : Should the word “Time” on the Timer Screen start to flash slowly, this is 

also a indication that the battery has reached a low value and should be changed soon.

To Use the Hands Free Carry Case (Sold Separately) which Can protect your Speed-Timer 3000 

when not in use. Will attach to your Belt for secure and easy access while recording shots. Just 

fold the flap back, attach the flap to the Velcro and slip it on your belt, or can be attached to your 

wrist, for "Hands Free" use while recording shots. Fold the flap around your wrist and attach to the 

Velcro for "Hands Free" use.

DISPLAY with a Speed-Timer 3000 (RF) Only:

Install a 9 volt Alkaline Battery in the battery compartment of the DISPLAY.

Note: If you purchased your Speed-Timer RF Timer and Display together the following may not be 

necessary as the ID would have been Factory Set,      Factory Setting is 0000 RF Off

Turn on the DISPLAY with the on/off switch located on the left side of the unit. Make a note of the 

ID displayed, on the screen, which will appear for approximately 5 Seconds. 

With the screen on the Speed-Timer 3000 (RF) blank, hold down the MODE key on the Speed-

Timer 3000 (RF) for 7-10 seconds. When you the letters ID release the key.

You will now see a four digit ID displayed on the Speed-Timer 3000 (RF) with the first digit 

flashing. Using the up and down arrow keys set the first number if required to the first number that 

the DISPLAY displayed when it was first turned on and press the MODE key. The second digit will 

now be flashing, again using the arrow key up or down to set this digit and press the MODE key. 

Repeat this process for all remaining digits and press the MODE key to finish.

Your timer is now set to communicate with this DISPLAY only! This setting will not change unless 

you repeat the above process.

Operating The Speed-Timer 3000 (RF) / DISPLAY

Make sure that your Speed-Timer 3000 (RF) is set to communicate with the DISPLAY as above.

Begin recording shots with your Speed-Timer 3000 (RF) and watch the DISPLAY display your 

times, Shots Fired, Walk Through Count Down etc.

When not in use, turn off the DISPLAY using the switch on the left side of the unit to conserve the 

battery life.

Always record the official time for any event as that

time displayed on the Speed-Timer 3000.

March 31 2017

Отзывы: