background image

27 

 

 

Solution 1. Easy setup [Recommended

 

Step 1

 Select the operating Band and click 

APPLY.

 

               

 

 

Step 2

 Easy Setup 

              Easy Setup proceeds to:   
               

  Data initial execution 

               

  Sync signal acquisition 

               

  HPA ON 

               

  ALC gain set 

               

  ASD ON 

               

  ALC ON to obtain Maximum DL Output Power 23dBm[Default] or Maximum Gain 80dB. 

               

  Real time isolation check 

 

Click Automatic Easy Setup. 

 

Easy Setup feature detects Sync signals from the input RF signal. 
If the Easy Setup processor does not receive a sync signal, it does not progress any further and 
performs the sync signal acquisition step. 

Содержание RSN-WiMAX-23 H

Страница 1: ...1 WiMAX 23 RSN WiMAX 23 L H User s Manual Please read this manual before operating this product After you finish reading this manual store it in a safe place for future reference...

Страница 2: ...is unit was tested with shielded cables on the peripheral devices Shielded cables must be used with the unit to insure compliance Important To comply with RF exposure requirement the antenna must be i...

Страница 3: ...cribes the specifications installation and operation of the WiMAX repeater Hardware and software mentioned in this document are subject to continuous development and improvement Consequently there may...

Страница 4: ...ch other can lead to severe damage to the repeater RF EXPOSURE INFORMATION A minimum separation distance of 7 9 inches 20cm must be maintained between the user and the external antenna of the repeater...

Страница 5: ...Control Unit 11 3 Hardware Installation 12 3 1 Check List of Items 12 3 2 Mounting 13 3 3 Grounding 15 3 4 Cable Connection 16 3 5 Power On 16 4 Operation 18 4 1 System Requirements 18 4 2 Network Se...

Страница 6: ...oltage Standing Wave Ratio ALC Automatic Level Control ALC feature prevents the repeater from exceeding its maximum output power by reducing the gain automatically ALC is used to adjust the gain to an...

Страница 7: ...function of reporting through the radio network There is only one physical RJ 45 port The local port provides an on site access to the repeater DHCP server at the local port enables Plug and Play by...

Страница 8: ...onnects the donor antenna 5 Alarm LED When the On site Alarm occurs the LED turns on When it operates normally the green LED turns on 6 UL Gain Ctrl To control only the UL Path gain through a simple s...

Страница 9: ...8 2 2 Internal Configuration MCU Sync Detec 1 MCU Main Control Unit 2 Sync Detec...

Страница 10: ...9 2 2 1 Block Diagram The following diagram explains how the WiMAX repeater amplifies the signal...

Страница 11: ...pment by drawing power from the general in wall AC outlets Specification Item Specification Operating Temp 0 C 40 C 32 F 104 F Humidity 20 90 RH Environmental Cooling method Convection Voltage AC110 2...

Страница 12: ...unit of the WiMAX repeater It controls and monitors operational parameters It is also responsible for generating alarms keeping event logs and performing many other functions CON 5 CON 11 Pin Map Por...

Страница 13: ...Cable Connection Power On 3 1 Check List of Items Index Items Quantity 1 Repeater 1 2 AC DC Adaptor 1 3 UTP Cross LAN Cable 1 4 AC Cord 1 5 Anchor Bolts 4 6 CD of the User s Manual 1 7 Quick Guide 1 I...

Страница 14: ...ing bracket which has 4 holes for the provided 5 16 fixing screws Step 1 Drill holes directly through the template Step 2 Install the set anchor bolts or the plastic anchor bolts on the holes Step 3 A...

Страница 15: ...14 Step 4 Lean the WiMAX to hang the topside of the Guide Ring on the mounting bracket and push toward the wall to mount Step 5 Fix the WiMAX using the 6 screws provided...

Страница 16: ...15 3 3 Grounding A rod on the left side is intended for a building ground Connect the ground cable to the rod...

Страница 17: ...Step 2 Connect a cable from a repeater s service antenna to the Server Antenna Port 3 5 Power On Step 1 Connect the power cord Step 2 Plug the power cord into a wall outlet Step 3 Turn on the power s...

Страница 18: ...t to a MAX value of 15dB by using an external switch combination Refer to the following diagram in regards to the switch combination Switch Combination 1 2 3 4 0dB 1dB 2dB 3dB 4dB 5dB 6dB 7dB 8dB 9dB...

Страница 19: ...llowing system requirements Windows 2000 Windows XP or Windows Vista Internet Explorer 6 0 Recommended or higher 128 MB RAM or higher Pentium processor or higher RJ 45 jack required 4 2 Network Setup...

Страница 20: ...on the Local Area Connection and select Properties to view the shortcut menu Step 4 Select Internet Protocol TCP IP and click Properties Step 5 Check Obtain an IP address automatically and click OK St...

Страница 21: ...0 4 2 2 Windows 2000 Step 1 Click the Start button point to Settings and then click Network and Dial up Connections Step 2 Right click Local Area Connection to see a shortcut menu and click Properties...

Страница 22: ...21 Step 3 Select Internet Protocol TCP IP and click Properties Step 4 Check Obtain an IP address automatically and click OK Step 5 Close all windows 4 2 3 Windows Vista...

Страница 23: ...22 Step 1 Click the Start button and Control Panel Step 2 Click Network and Internet Step 3 Click Network and Sharing Center...

Страница 24: ...23 Step 4 Click View status of Local Area Connection Step 5 Click Properties and a caution pop up window will appear Click OK...

Страница 25: ...24 Step 6 Select Internet Protocol Version 4 TCP IPv4 and click Properties Step 7 Check Obtain an IP address automatically and click OK...

Страница 26: ...25 Step 8 Close all windows...

Страница 27: ...ically sets up to the PC s time setting when you click APPLY 4 4 2 Auto Refresh This sentence makes no sense You should change it to When you click on the Auto Refresh button the Web GUI screen automa...

Страница 28: ...isition HPA ON ALC gain set ASD ON ALC ON to obtain Maximum DL Output Power 23dBm Default or Maximum Gain 80dB Real time isolation check Click Automatic Easy Setup Easy Setup feature detects Sync sign...

Страница 29: ...28 Step3 Click OK Step 4 Setup will automatically begin This process takes approximately 1 minute Result 1 Constant Maximum DL Output Power 23dBm If the DL Input Power 57dBm...

Страница 30: ...example case for a repeater with 23dBm maximum output power 80dB maximum gain 35dB gain control range If the signal 47dBm and the ALC is set as 23dBm the gain will be 70dB to adjust to the output powe...

Страница 31: ...nge assuming ASD Level 25dBm ASD Time ASD Count are already fixed at 3seconds 10times If the composite output power is 25dBm ASD Level and higher the repeater will shutdown for 3seconds ASD Time If th...

Страница 32: ...31 Solution 2 DL Output Power Max 23dBm Step 1A Repeat Step 1 through Step 4 Step 2A Change the level at Automatic Level Control and then APPLY Result Constant output power set as the ALC Level...

Страница 33: ...ution 3 Manual Gain Setting Gain Not Recommended Step 1B Repeat Setps1 through 4 Step 2B Read the DL Input Power and the gain controlled by the Easy Setup Step 3B Turn off HPA Step 4B ALC must be turn...

Страница 34: ...33 Step 5B Change the DL gain and the UL gain Step 6B Turn on HPA Result DL and UL gain are fixed and the output power depends on the input power...

Страница 35: ...s Alarm Status Alarm Range Alarm If an alarm occurs the alarm LED on the repeater will turn on Please refer to the troubleshooting section of this manual No Change in values on the alarm range is reco...

Страница 36: ...of these 3 the alarm LED is on If the alarm is by over input or over output the ASD algorithm is applied If the RF environment is normal the LED is automatically turned OFF For Out of sync it searches...

Страница 37: ...36 Problem Cause Solution Cannot communicate with the repeater 1 Click My Network places View network connections Right click on the Wireless Network Connection and then click Disable...

Страница 38: ...roblem Cause Solution 2 Right click on the Local Area Connection and then click Disable After clicking Disable click Enable again 3 Double click the Local Area Connection and then click Support tap Re...

Страница 39: ...38 Problem Cause solution 4 Open the Internet Browser and then select Tools Internet Options Click Delete Files button in the Temporary Internet files section...

Страница 40: ...39 Problem Cause Solution 5 Click Start and select Run Type ping 192 168 0 1 t and click OK...

Страница 41: ...Peak to Peak Fc 16 5MHz 13 dBm RBW 100kHz Fc 18 5MHz 13 dBm RBW 1MHz Fc 20MHz 37 dBm RBW 1MHz ACP Fc 23MHz 37 dBm RBW 1MHz 1850 1995 MHz Below the noise floor 806 826MHz and 851 869MHz Below the noise...

Страница 42: ...74 mm 8 27 x 11 4 x 2 9 inch Weight 5Kg 11lbs 7 Appendix WiMAX Band Frequency chart AB BC CD EF FH HG Band BRS Band Frequency Range Band A 2502 2518 5 MHz Band B 2518 5 2535 MHz Band C 2535 2551 5 MHz...

Страница 43: ...ll not apply to the following including but not limited to damage which occurs in installation applications and uses for which this product was not intended altered product or serial numbers cosmetic...

Страница 44: ...ange procedure below 1 Call Tech Support for troubleshooting 2 If the device has a hardware problem R tron will replace it if it is within warranty A RMA number will be issued for the return 3 R tron...

Отзывы: