2.4.2.
R-Link with 60pin Flex cable
Disconnect the Ribbon cable between the monitor’s monitor panel and the monitor PCB.
Connect the daughter PCB’s ribbon cable
CAR-IN
to the ribbon cable base of the monitor
panel. For this procedure you may either use the original ribbon cable or the ribbon cable of
daughter PCB. Make sure that the connector pins of each pin connector are faced to the
platinum before clipping them.
Connect the daughter PCB’s ribbon cable
PNL OUT
to the ribbon cable base of the
monitor panel’s short original Flex cable, by using the enclosed pin connector (pay same
attention to platinum faced installation of the connector pins!).
Carefully fix the daughter PCB to the monitor`s rear side by using the enclosed longer screws
2.4.2.1.
Warning notes, concerning the installation of ribbon cables:
1) The contacting ends of ribbon cables always have to be installed in a straight and precise
180° position to the connector. Each deviation from a perfect contact position will curse
faulty contact and even danger of short circuit
2) The ribbon cable’s contacting side always has to correspond to the contacting side of the
connector, concerning the mounting position.