Technical description |
EN
2.8 System states
System status
Display
Comment
Remote access
If network nodes are accessed from a master, the
"ɔ"
symbol is shown in the
display.
Highspeed mode
for
example
Wenn
all
Network nodes have their receivers permanently switched on so that all
new data can be exchanged immediately within the network, this is indicated by
two dots in the upper area of the display
Bus connection
for
example
When a connection to the bus is established, the bus number ("0"=M-Bus) and
the set primary address are briefly displayed on this bus. In the example, the
network node with the primary address "03" was connected to the M-Bus.
IR master mode
This operating mode can be activated by briefly pressing (<0.5 seconds) the
button
MODE
can be started. This operating mode signals that other IR devices
(in operating mode
IR Slave Mode
) can now be connected. This operating mode
is automatically terminated after 10 seconds of inactivity.
Insertion
for
example
If in the operating mode
IR Master Mode
a non-registered IR-capable
measuring device (for example WHE467) is connected, this can be inserted in the
network node. The display shows the last 4 digits of the meter (in the example:
20000123). To confirm, press the key
DISPLAY
. The device is then registered
and the operating mode
Search mode
is started.
Delete
for
example
If in the operating mode
IR Master Mode
an already registered IrDA-capable
measuring device is connected, this can be removed from the network node.
The last 4 digits of the measuring device are shown in the display (example:
20000123). To confirm, press the key
DISPLAY
. The device is then deleted and
the operating mode
Search mode
is terminated if necessary.
Click to copy
for
example
Copying the network data of a network node is possible if the new network node
is in the operating mode
IdLE
is located.
Briefly press the red button
MODE
on the network node with the data to be
copied and place both network nodes with open housings in front of each other.
In the display of the copying (old)
Network node is
COPY
is displayed. Press the blue button to confirm
DISPLAY
.
The network nodes must remain in front of each other during the copying
process. Copying takes up to 20 minutes depending on the data volume.
When copying is complete, the new network node is automatically in the
operating mode
Search Mode
.
After receiving the uploaded devices, the network node switches to the operating
mode
Standard mode
and must be added manually to the network node
network.
2.9 Error codes
An 'x' in the error level 'b' and 'C' describes how often this error has occurred. If the error of a group occurs more than
9 times, a dash '-' is shown there.
09.03.2023
58
Содержание Qnode 5.5
Страница 186: ...Dimensions DE 8 Dimensions RNN5 000M 0x RNN5 000M 1x 09 03 2023 LUM5 00AM DES N55G2 B 186...
Страница 187: ...Mounting DE 9 Mounting 100 mm 184 mm 6 mm a b a b 160 184 mm 1 1 2 2 3 3 09 03 2023 LUM5 00AM DES N55G2 B 187...
Страница 188: ...Mounting DE 4 Abbildung 1 RNN5 000M 0x 4 Abbildung 2 RNN5 000M 1x 09 03 2023 LUM5 00AM DES N55G2 B 188...
Страница 189: ...Mounting DE 09 03 2023 LUM5 00AM DES N55G2 B 189...