![QUNDIS Qheat5 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/qundis/qheat5/qheat5_installation-manual_3771258028.webp)
Note national and country-specifi c regulations
concerning the use of immersion sleeves.
4
5
1
2
3
4
28
Sealing the device
Sealing the temperature sensor in an immersion sleeve
Noting the meter readings
(1) Thread the wire of the seal through the
seal holes on the threaded sensor fi tting
and immersion sleeve.
(2) Route the seal wire around the
tee-piece.
(3) Insert the wire through the available
opening in the seal body.
(4) Wind the wire tightly by turning the
wing in the seal.
(5) Break the wing off the seal.
Sealing is guaranteed by breaking
the seal off.
• Note the installation date, meter
numbers, any seal numbers
• Note the old and new meter
readings
Dispose of a used
device according to
national waste disposal
regulations.
• Remove the installation protection