Quincy QMD 120 Скачать руководство пользователя страница 20

Module involved

Cause

Message on the
display

How to clear the
alarm

Alarm LED status

PDP
(English:Pressure
Dew Point) sensor

PDP above or equal
to the minimum
value of the PDP
range

PDP is not
connected

Verify if the PDP
sensor is correctly
connected and if it
is not damaged.

Blinking

 

PDP lower than or
equal to the
minimum value of
the PDP range

PDP measure is
wrong

Verify if the PDP
sensor is correctly
connected and if it
is not damaged.

Blinking

 

PDP sensor supply
voltage < 20 V

PDP supply is in
fault

Verify if the sensor
supply voltage is
correct.

Blinking

 

PDP more than 10
°C (18 °F) above
the desired setpoint

PDP meas > the
setpoint

The alarm is
automatically
cleared when the
desired dew point is
reached.

Blinking

Service

Running hours >
programmed
service hours A, B
or C

Running hours >
service hours X (X
= A, B or C)

Perform the
requested
maintenance (A, B
or C). Next, enter
the Alarm menu,
select Service
Alarm, press the
ENTER button and
keep it pressed
during minimum 5 s.

Blinking

24 V supply

Supply voltage < 18
V

24 V supply is in
fault

Contact your
supplier

Blinking

Controller

Controller hardware
fault

Internal error

Reset all settings to
the default value.
Switch off the
controller and
switch it on again.
Call your supplier if
the fault persists.

Lit continuously

When an alarm is active, relay K01 is closed (relay X15, contacts 9 en 10) . When all the alarms
are cleared, K01 is open.

Acknowledgement of the alarms does not affect the status of K01 or the status of the red LED.

4.5

Editing parameters

During parameters editing (Chapter 

Selection menu

 , menu item 

Settings 

), the display shows an

image similar to the following:

Instruction book

18

2920 7111 40

Содержание QMD 120

Страница 1: ...Quincy Heatless adsorption air dryers QMD 55 QMD 75 QMD 95 QMD 120 QMD 140 QMD 190 QMD 230 QMD 275 QMD 350 QMD 420 QMD 550 HE version Instruction book...

Страница 2: ......

Страница 3: ...ce Any unauthorized use or copying of the contents or any part thereof is prohibited This applies in particular to trademarks model denominations part numbers and drawings This instruction book is val...

Страница 4: ...REPAIR 8 2 General description 10 2 1 GENERAL DESCRIPTION 10 2 2 OPERATION 11 3 Electric diagram 14 4 AirLogic controller 15 4 1 CONTROL PANEL 15 4 2 MAIN SCREEN 16 4 3 SELECTION MENU 16 4 4 ALARM SCR...

Страница 5: ...WEB SERVER 58 5 18 PROGRAMMABLE SETTINGS 67 6 Installation 68 6 1 DIMENSION DRAWINGS 68 6 2 INSTALLATION PROPOSAL 68 7 Electrical connections 72 8 Operating instructions 73 9 Maintenance 75 9 1 MAINTE...

Страница 6: ...12 Instructions for Use 84 13 Guidelines for inspection 85 14 Pressure Equipment Directives 86 15 Declaration of conformity 87 Instruction book 4 2920 7111 40...

Страница 7: ...dryer is not considered capable of producing air of breathing quality To obtain air of breathing quality the compressed air must be adequately purified according to the applicable legislation and sta...

Страница 8: ...ped and that the isolating switch is open and locked before any maintenance or repair As a further safeguard persons switching on remotely controlled machines shall take adequate precautions to ensure...

Страница 9: ...a hose is fully depressurized before disconnecting it 3 Persons switching on remotely controlled machines shall take adequate precautions to ensure that there is no one checking or working on the mach...

Страница 10: ...e starting equipment 7 Close the dryer air outlet valve before connecting or disconnecting a pipe 8 Before removing any pressurized component effectively isolate the machine from all sources of pressu...

Страница 11: ...er tear off or remove the latter flush abundantly with fresh water over the clothing until all refrigerant is flushed away then seek medical first aid 21 The following safety precautions are stressed...

Страница 12: ...dryers are available in versions to reach a pressure dew point down to 20 C 4 F 40 C 40 F or 70 C 94 F and are standard equipped with a AirLogic electronic controller The dryers are designed for indoo...

Страница 13: ...scing inlet filter is supplied loose not shown on the images 2 2 Operation General The construction of the air dryer is simple reliable and easy to service A dryer module basically consists of two tow...

Страница 14: ...the second tower is being regenerated Regeneration of the desiccant is achieved by means of purge air from the drying tower The compressed air entering the dryer is led to one of the towers by means...

Страница 15: ...operation the controller jumps automatically to status 5 or 12 equalization phase After that the Stop status 0 will be reached The following start command will restart the sequence from the state 2 o...

Страница 16: ...lectric diagram can be found in the electrical cabinet and on the CD ROM DVD or USB supplied with the unit Drawing number Controller type 9827 2940 00 Basic controller 9827 2939 00 Graphic controller...

Страница 17: ...lly Displays the next alarm cyclically Selects the parameter Increments the data value No action ENTER Displays the selection menu Cancels the displayed alarm for one minute alarm acknowled gment Sele...

Страница 18: ...nimated icon is present Icon Description Rotating arrow Active when the dryer is in its working phases Still vertical bars Visualized when the dryer is in the FREEZE status Still square Visualized whe...

Страница 19: ...hen one or more alarms are active the alarm screen overrides the main screen In the upper right area the current alarm number and the total active alarms number are visualized In the lower area the cu...

Страница 20: ...Running hours programmed service hours A B or C Running hours service hours X X A B or C Perform the requested maintenance A B or C Next enter the Alarm menu select Service Alarm press the ENTER butt...

Страница 21: ...d value How to modify a parameter Step Button involved Action 1 RIGHT or LEFT To select the parameter to be modified 2 ENTER Starts the modification procedure If the parameters is a selection value e...

Страница 22: ...h French Spanish Italian Portuguese German Russian 3 Display timeout 5 min 1 999 min 4 PDP control Enables or disables the PDP sensor Off On or Off 5 Dewpoint setpnt Fixes the target for the PDP Maxim...

Страница 23: ...nd modify programmable parameters the regulator has a control panel provided with LED s indicating the status of the dryer A display indicating the operating conditions or a fault Keys to control the...

Страница 24: ...unction keys of the controller Parts and functions Reference Designation Function 1 Display Shows the dryer operating condition and a number of icons to navigate through the menu 2 Pictograph Automati...

Страница 25: ...n the dryer is stopped the icon stands still When the dryer is running the icon is rotating Machine control mode Local start stop Remote start stop Network control Automatic restart after voltage fail...

Страница 26: ...emperature Digital input Special protection System icons Icon Description Dryer Fan Frequency converter Drain Filter Motor Failure expansion module Network problem General alarm Menu icons Icon Descri...

Страница 27: ...ms Warnings shutdowns Counters Test Settings Service Event history saved data Access key User password Network Set point Info General settings Navigation arrows Icon Description Up Down Instruction bo...

Страница 28: ...s shown automatically when the voltage is switched on and one of the keys is pushed It is switched off automatically after a few minutes when no keys are pushed Six different main views can be chosen...

Страница 29: ...cons These icons are always shown in the main screen e g Dryer stopped or running Dryer status Optional icons These icons are only shown if their corresponding function is activated e g week timer aut...

Страница 30: ...modify programmable settings Reset To reset a timer or message To activate an action button highlight the button by using the Scroll keys and press the Enter key To go back to the previous menu press...

Страница 31: ...rt and is highlighted active When the Chart Low Resolution is selected a chart showing the parameter per day is shown on the main screen Each point is the average of 1 hour The screen shows 10 days Th...

Страница 32: ...efault the Inputs icon is selected The status bar shows the name of the menu that corresponds with the selected icon Use the Scroll keys to select an icon Press the Enter key 2 to open the menu or pre...

Страница 33: ...ears Text on figure 1 Inputs 2 Pressure vessel A 3 Pressure vessel B 4 Blower pressure 5 Inlet dryer The screen shows the first items of a list of all inputs with their corresponding icons and reading...

Страница 34: ...ure Starting from the Main screen see Main screen Move the cursor to the action button Menu and press the Enter key Following screen appears Move the cursor to the Outputs icon using the Scroll keys P...

Страница 35: ...Function To call up The running hours The number of dryer starts The number of hours that the regulator has been powered The operational state timers Procedure Starting from the Main screen see Main...

Страница 36: ...eneration cycles vessel A integer that counts how many cycles vessel A has performed Regeneration cycles vessel B integer that counts how many cycles vessel B has performed Standby time shows how long...

Страница 37: ...and press the Enter key Following screen appears Using the Scroll keys move the cursor to the Event History icon see above section Menu icon The list of last shutdown and emergency stop cases is shown...

Страница 38: ...en Move the cursor to the action button Menu and press the enter key 2 following screen appears Using the scroll keys 1 move the cursor to the test icon see above section Menu icon Press the Enter key...

Страница 39: ...were carried out in the past To modify the programmed service intervals Procedure Starting from the Main screen see Main screen Move the cursor to the action button Menu and press the Enter key Follo...

Страница 40: ...e controller will launch a service warning when either 4000 running hours or 4380 real hours are reached whichever comes first Note that the real time hours counter keeps counting also when the contro...

Страница 41: ...vice plan 3 and press Enter Following screen appears Text on figure 1 Service plan 2 Level 3 Running hours 4 Real time Next Service Text on figure 1 Next service 2 Level 3 Running hours 4 Actual In th...

Страница 42: ...ns menu Menu icon Protections Function To call up the protections Before resetting a warning or shut down message always remedy the problem Frequently resetting these messages without remedying may da...

Страница 43: ...ands for the dryer To program time based change over commands for the net pressure band Four different week schemes can be programmed A week cycle can be programmed a week cycle is a sequence of 10 we...

Страница 44: ...e The first item in this list is highlighted in red Select the item requested and press the Enter key on the controller to modify Programming week schemes Select Week action schemes and press Enter A...

Страница 45: ...atically selected and highlighted in red Press the Enter key on the controller to set an action for this day Text on figure 1 Week Action Scheme 1 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7...

Страница 46: ...list by using the Scroll keys on the controller When ready press the Enter key to confirm Text on figure 1 Monday 2 Actions 3 Remove 4 Start 5 Stop 6 Pressure Set point 1 7 Modify A new window opens T...

Страница 47: ...day 2 Start 3 Save 4 Modify A pop up window opens Use the or key of Scroll keys to modify the values of the hours Use the or Scroll keys to modify the minutes Text on figure 1 Monday 2 Time 3 Save 4 M...

Страница 48: ...oll keys on the controller to select the correct actions Press the Enter key to confirm Text on figure 1 Monday 3 Are you sure 4 No 5 Yes 6 Save 7 Modify Press the Escape key to leave this window The...

Страница 49: ...ogramming the week cycle A week cycle is a sequence of 10 weeks For each week in the cycle one of the four programmed week schemes can be chosen Select Week Cycle from the main Week Timer menu list Te...

Страница 50: ...dow opens Select the action example Week Action Scheme 1 Text on figure 1 Week Cycle 2 Week 1 3 Week Action Scheme 1 4 Week Action Scheme 2 5 Week Action Scheme 3 6 Modify Check the status of the Week...

Страница 51: ...tive 6 Remaining Running Time A new window opens Select Week 1 to set the Week Timer active Text on figure 1 Week Timer 2 Week 3 Week Timer Inactive 4 Week 1 Press the Escape key on the controller to...

Страница 52: ...controller to Modify Text on figure 1 Week Timer 2 Week Action Schemes 3 Week Cycle 4 Status 5 Remaining Running Time This timer is used when the week timer is set and for certain reasons the dryer mu...

Страница 53: ...Move the cursor to the action button Menu and press the Enter key Following screen appears Using the Scroll keys move the cursor to the Info icon see above section Menu icon 5 15 Modifying settings M...

Страница 54: ...reen appears Using the Scroll keys move the cursor to the Settings icon see above section menu icon Press the Enter key Following screen appears The screen shows a number of icons Icon Function Networ...

Страница 55: ...tings icon as described above and press the Enter button 2 Following screen appears Text on figure 1 Network 2 Ethernet 3 CAN A red selection bar is covering the first item Ethernet Use the key of the...

Страница 56: ...is covering the first item Ethernet Using the Scroll keys move the cursor to the setting to be modified e g Ethernet and press the Enter button 2 A pop up screen appears Use the or key to select the...

Страница 57: ...the first item Language in use Use the key of the Scroll keys to select the setting to be modified and press the Enter key A pop up screen appears Use the or key to select the required parameter and p...

Страница 58: ...gh after regeneration and cooling PDP switching temperature the PDP should not increase to this setting before the vessels are switched when the dryer is in standby mode PDP alarm offset the PDP alarm...

Страница 59: ...pop up menu appears Use the scroll keys to enter the password of the new security level Press the Enter key to confirm the change User password If the password option is activated it is impossible for...

Страница 60: ...for the pressure dew point the relative humidity and the LAT set point appears 1 Extra 2 Dryer PDP 3 Relative Humidity 4 LAT Set point 5 17 Web server The controllers have a built in web server that a...

Страница 61: ...from your computer or a USB to LAN adapter see picture below USB to LAN adapter for Windows XP USB to LAN adapter for Windows 7 Use a UTP cable CAT 5e to connect to the controller see picture below In...

Страница 62: ...rk card Go to My Network places 1 Click on View Network connections 1 Select the Local Area connection 1 which is connected to the controller Click with the right button and select properties 1 Instru...

Страница 63: ...the web server Configure the web interface The internal web server is designed and tested for Microsoft Internet Explorer 6 7 and 8 Other web browsers like Opera and Firefox do not support this inter...

Страница 64: ...Click on the Connections tab 1 and then click on the LAN settings button 2 In the Proxy server Group box click on the Advanced button 1 Instruction book 62 2920 7111 40...

Страница 65: ...addresses 192 168 100 1 and 192 168 100 2 Now you add 192 168 100 100 and separate the 3 IP addresses by putting semicolons between them 1 see picture Click OK 2 to close the window Viewing the contro...

Страница 66: ...tion menu see picture below If a license for ESi is foreseen the menu contains 3 buttons machine shows all machine settings Es shows the ESi status if a license is provided Preferences allows to chang...

Страница 67: ...Counters give an overview of all actual counters from controller and machine Info status Machine status is always shown on the web interface Digital inputs Gives an overview of all Digital inputs and...

Страница 68: ...This screen only shows the running hours It is also possible to show the actual status of the service interval ES screen controller If an ESi license is provided the button ES is shown in the navigat...

Страница 69: ...5 18 Programmable settings Description The regulation and safety devices are factory adjusted to obtain optimum performance of the dryer No adjustments are required Instruction book 2920 7111 40 67...

Страница 70: ...o be able to replace the filter cartridges without the need having to disassemble the piping Make sure that all pipes filters valves etc are clean and that they are installed correctly with or without...

Страница 71: ...ow images for the references used Never overload the dryer as a too high air speed may damage the desiccant Therefore it may be recommended to install the air dryer upstream of the air receiver to pre...

Страница 72: ...ll stop the purge air flow at the end of the cycle 2 minutes and it will restart when the air compressor resumes to deliver compressed air When the air receiver is installed upstream the dryer the loa...

Страница 73: ...Instruction book 2920 7111 40 71...

Страница 74: ...e air dryer must be earthed and protected by fuses against short circuiting Consult the electric diagram delivered with the dryer Before switching on the main power supply check the voltage requiremen...

Страница 75: ...rnal outlet valve 13 If applicable close the bypass valves of the dryer 14 Open the air supply towards the PDP sensor dryers with PDP sensor If the application allows air that is not completely dry th...

Страница 76: ...er so that the application will still receive compressed air 2 Close the external inlet valve between the compressor and the dryer and the external outlet valve between the dryer and the dry air consu...

Страница 77: ...maintenance schedule Frequency Service plan Activity Daily Check the display panel for information and service messages Every 6 months or every 4000 hours of operation 1 A Check for damaged wiring or...

Страница 78: ...with the local recommendations and environmental legislation Electronic components are subject to the EU Directive 2012 19 EC for Waste Electrical and Electronic Equipment WEEE As such these parts mu...

Страница 79: ...w Check whether the compressor provides enough air for the application The inlet temperature is too high Check the compressor aftercooler Free water in the dryer Check the water separator and the drai...

Страница 80: ...d air effective inlet pressure barg 14 Maximum compressed air effective inlet pressure psig 203 Minimum compressed air effective inlet pressure barg 4 Minimum compressed air effective inlet pressure p...

Страница 81: ...umina Activated alumina Desiccant amount per vessel kg 7 4 7 4 9 9 12 4 14 8 18 8 Desiccant amount per vessel lb 16 3 16 3 21 8 27 3 32 6 41 45 Inlet filter 1 QCF 75 QCF 100 QCF 175 QCF 175 QCF 300 QC...

Страница 82: ...40 140 140 140 Minimum volume flow at inlet l s 20 20 20 30 30 Minimum volume flow at inlet cfm 42 4 42 4 42 4 63 6 63 6 HE version PDP 40 C QMD 55 QMD 75 QMD 95 QMD 120 QMD 140 QMD 190 Volume flow at...

Страница 83: ...bar 0 159 0 238 0 405 0 238 0 447 Pressure drop at maximum flow psi 2 31 3 45 5 87 3 45 6 48 Time to half a cycle s 87 87 87 87 87 Regeneration time s 65 65 65 65 65 Pressurization time s 20 20 20 20...

Страница 84: ...sel kg 10 9 13 0 16 5 10 9 13 0 16 5 Desiccant amount per vessel lb 24 0 28 7 36 4 24 0 28 7 36 4 Inlet filter 1 QCF 75 QCF 100 QCF 175 QCF 175 QCF 300 QCF 300 Outlet filter 1 QPF 75 QPF 100 QPF 175 Q...

Страница 85: ...kg 13 0 16 5 16 5 16 5 Desiccant amount per vessel lb 28 7 36 4 36 4 36 4 Inlet filter 1 QCF 300 QCF 400 QCF 550 QCF 550 Outlet filter 1 QPF 300 QPF 400 QPF 550 QPF 550 Maximum air outlet temperature...

Страница 86: ...The design pressure and temperature of this pressure bearing part must be clearly indicated on the data label 5 If installed the safety valve must correspond with pressure surges of 1 1 times the maxi...

Страница 87: ...r the design are shown and or referred to The Declaration of Conformity Declaration by the Manufacturer is part of the documentation that is supplied with this air dryer Local legal requirements and o...

Страница 88: ...66 I 5 150 19 5 1627 6307 96 14 10 to 66 I 5 150 24 7 Recommendation of the manufacturer for the re inspection time Following actions are to be executed by authorized service personnel unless stated...

Страница 89: ...States 2 Applicable directives 3 Standards used On the Declaration of Conformity Declaration by the Manufacturer the harmonized and or other standards that have been used for the design are shown and...

Страница 90: ......

Страница 91: ......

Страница 92: ...No 2920 7111 40 2017 06 Printed in Belgium Performance You Demand Reliability You Trust www quincycompressor com...

Отзывы: