background image

PAGE 2

     Unit should be turned off and let stand to allow heating element to cool to room temperature before 
cleaning.  Clean exterior surfaces with a damp cloth or with an all-purpose cleaner.  Only area around 
heating "element well" should be cleaned.  Do not get cleaning solutions on actual heating element 
surface.  Heating element area should be kept free from all debris at all times to eliminate the risk of fire. 

   Tech Support

If you have any questions or need technical assistance, please contact Quincy Lab customer support at    

 

 

  Voice: 

 

800-482-HEAT   Quincy 

Lab, 

Inc. 

    

  Fax: 

 

773-622-2282 

   1925 

North 

Leamington 

Avenue 

  

 

 

Email:  [email protected]   

Chicago, Illinois  60639

  Limited Warranty

Quincy Lab, Inc. warrants to the original purchaser that this product will be free from defects in material 
and workmanship under normal use throughout the warranty period. The standard warranty period for

this instrument is 18 months, (3-year coverage on the heater element), from date of 
shipment. Please refer to your invoice or shipping documents to determine the 
effective warranty period.  This warranty covers parts and labor (labor at factory 
only), and shipping cost for replacement parts.

    A

U T

I O N

CAU

TIO

N

Place the unit face down on a work surface.

Separate the legs of the "no-skid" foot cover strips and place over 
the exposed bottom edge of each end cap. 

 FIG. 1

Place the unit upright, with the exposed element facing up and 
plug the unit into a grounded outlet.  Turn the unit on and allow it to 
come up to the operating temperature (approx. 10-12 minutes).  

FIG. 1

Replacement Components - Model's: 03-160, 13-160, 23-160

COMPONENT

MODEL PART NUMBER

COMPONENT

MODEL PART NUMBER

1212-03

301-2251

03-160

13-160

23-160

Universal

  

1212-23

Replacement Element

101-1803

1212-13

6' Cord & Plug 

Toggle Switch

Indicator Lamp  

101-2202

Replacement Element

Replacement Element

115V 18GA/3 wire

Universal

Universal

 Set-up

 Maintenance

Place the plastic workpiece to be formed on the work 
surface with the area to be formed over the element. Turn 
the piece over at regular intervals.  This will ensure that the 
plastic is heated evenly throughout its thickness and that it 
is not overheated, causing the plastic to bubble or even 
scorch.  Product guiderails are provided on each side of the 
unit to help keep part perpendicular to heating element for 
accurate heat-through.  Various types of plastics, as well as 
thicknesses, will require different heat-through times before 
it can be formed. Trial and error testing of scrap pieces will 
ensure the best possible results for the actual parts.

 General Operation

CAU

TIO

N

CAU

TIO

N

WORK SURF

ACE MA

Y BE HO

T

Product Guides

Work Piece

FIG. 2

Отзывы: