2  RIVA ADVANCE COMBI USER MANUAL

Dear Customer:

Thank you for buying a Biasi Riva Advance Combi.

The  Riva Advance  Combi  is  a  high  efficiency  condensing,  wall  mounted  gas  boiler  which 

provides central heat.

We realize that it is not possible to answer all questions about the Riva Advance Combi in this 

manual. Reading this installation manual does not make the reader an expert in all aspects 

of installation and operation, and does not replace the need for a qualified, licensed heating 

contractor. We urge you to contact your installing contractor or distributor if you are in question 

about any aspect of your boiler’s performance. Our main concern is that you are satisfied with 

your boiler and its performance. We require that your contractor complete efficiency tests using 

instruments.

The external controls and accessories listed in this manual (excluding those supplied inside the 

boiler) are intended to serve as guidelines rather than specific recommendations. We realize 

that other makes and models of such devices are available and can be used as successfully as 

those we specify. The installing contractor is the best judge of a system’s specific requirements, 

as well as the local availability of certain makes and models of controls and accessories. The 

preceding does not apply, however, to the equipment that comes with every boiler, such as 

the  overheat  control  and  pressure  relief  valves. 

The  installation  of  the  specific  devices 

supplied with every boiler is absolutely necessary to the safe operation of the boiler and 

protection of the heating system.

All BIASI wall hung boilers are built in accordance with the ASME boiler and pressure vessel 

code, and bear the “H” stamp. The Entire range of applications for the Riva Advance Combi 

has been tested to standard 

ANSI Z21.13/

CSA 4.9 and is CSA compliant.

 

This Riva Advance Combi has a 2 year warranty, a copy of which is provided with the boiler. 

Please be sure to return the warranty registration card as the warranty will be void without your 

boiler’s serial numbers (located on the ratings label affixed to the boiler), date of installation 

and the name of your installer being on record in our files.

Thank you for purchasing our Riva Advance Combi. If you have questions or comments, please 

don’t hesitate to contact us immediately. Our goal is 100% customer satisfaction.

QHT inc.

Содержание Riva ADVANCE COMBI

Страница 1: ...ot use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you can not reach your gas supplier call the fire department Inst...

Страница 2: ...s those we specify The installing contractor is the best judge of a system s specific requirements as well as the local availability of certain makes and models of controls and accessories The precedi...

Страница 3: ...9 LCD General Features 4 10 11 Instructions for Use 5 12 17 Warnings 5 1 12 Refilling Procedure 5 2 12 Lighting Operating Instructions 5 3 13 Temperature Unit Setting C or F 5 4 13 Central Heating Cir...

Страница 4: ...qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been under water Do not store or use gasoline or other flammable vapors...

Страница 5: ...often confused with those of influenza and the highest incidence of poisoning occurs at the onset of cold weather or during flu season A victim may not experience any symptoms only one symptom or a fe...

Страница 6: ...at all times Keep the boiler area clean and free of all fire hazards Please read the literature and warranties supplied by the manufacturers of the various accessory equipment This equipment is warra...

Страница 7: ...rotection system to prevent frost damage which can occur in areas susceptible to very cold weather conditions Boiler operation recognition system should the boiler not be used for longer than 24 hours...

Страница 8: ...2000 4500 ft MBH 112 5 Max Exhaust temperature F 190 GAS FLOW RATE Gas Min Max Natural ft h 31 0 121 0 Propane lb h 1 5 5 7 CLEARANCE TO COMBUSTIBLES Front in 18 Back in 0 Top in 10 Sides in 2 Bottom...

Страница 9: ...button 7 Function switch and Central heating temperature adjustment knob 8 Domestic hot water temperature control knob 4 5 6 7 8 bar 3 1 2 H Figure 3 1 Figure 3 3 Figure 3 2 3 3 Piping Connections A G...

Страница 10: ...ostat intervention lockout E03 General lockout E10 Flue probe intervention lockout E11 Flame detection error E04 Faulty primary circuit no water or absence of flow E05 Faulty fan control system E06 Fa...

Страница 11: ...spark Flame present Burner on bar Pump operating C Variable temperature expressed in C bar Variable expressed in bar if the pressure sensor is installed Set D h w visible for 10 sec all other symbols...

Страница 12: ...a built in anti freeze system that operates the boiler when the temperature is below 41 F Therefore when the boiler is not lit or used in cold weather with consequent risk of freezing do not switch of...

Страница 13: ...tion The LCD display shows the sequence figure 5 2 3 If the appliance will not operate follow the extinguishing instructions on page 16 and call your service technician or gas supplier Figure 5 2 5 4...

Страница 14: ...temperature alters the gas flow at the burner according to the thermal demand in the system So it is usual to see the burner lit at the minimum level for more or less long periods 5 Adjustment of cen...

Страница 15: ...indicates if the set temperature has been reached Request for heating power If the boiler requests heating power you can see the sequence on the LCD display in Figure 5 8 Figure 5 7 From 41 to 59 F Be...

Страница 16: ...ect not to use the boiler for a long period Switch off the electricity supply to the boiler by means of the circuit breaker Shut off the gas supply cock connected to the gas inlet pipe and the cock co...

Страница 17: ...re the demand is at a low level or with the temperature set to the minimum it is normal to see a cycle of lighting and extinguishing of the burner when running Regulate the domestic hot water temperat...

Страница 18: ...the external temperature may be lower than 32 F it is suggested to leave the system running setting the room thermostat at a low temperature When the boiler is completely switched off for a long peri...

Страница 19: ...s the reset button 6 Figure 6 2 on the boiler control panel Signal given by the LCD display Figure 6 3 For the first light up and following maintenance procedures for the gas supply it may be necessar...

Страница 20: ...ot happen and to decrease the pressure to a normal value 14 5 psi it is advisable to vent some of the water in the appliance through the bleed valves present in the heating system Figure 6 4 If water...

Страница 21: ...freight pre paid QHT and Biasi will not be responsible for 1 Components that are part of the heating system but were not manufactured by Biasi or QHT as part of the boiler 2 The workmanship of the ins...

Страница 22: ...22 RIVA ADVANCE COMBI USER MANUAL...

Страница 23: ......

Страница 24: ...1796220640 17962 2064 0 2712 24A4 USA 06 07 2012 N...

Отзывы: