14 RIVA ADVANCE COMBI USER MANUAL
5.5 Central Heating Circuit Temperature:
1 Turn the selector 7 as in Figure 5.5.
2 The output temperature of c.h. water is
adjustable from a minimum of about 100
°F to a maximum of about 185 °F (Figure
5.5), by turning the knob 7.
3 The LCD display shows the sequence in
Figure 5.6.
4 Adjustment of the boiler temperature
alters the gas flow at the burner according
to the thermal demand in the system.
So it is usual to see the burner lit at the
minimum level for more or less long
periods.
5 Adjustment of central heating. Output
on the boiler is automatic. The greatest
output is factory pre-set, however, it can
be reduced according to actual system
requirements. These adjustments must
be carried out by a qualified person;
therefore we advise you to contact your
installer or Service Agent.
Figure 5.5
8
7
Figure 5.6
5. Instructions For Use Cont.