ENGLISH
6 - Edition 10/2014 Cod. 2200780133 00 -
8.0 POSITION OF PLATES
8.1 POSITION OF THE DANGER PLATES (Fig. 4)
The plates fitted on the compressor unit are part of the machine; they have been applied for safety purposes and must
not be removed or spoiled for any reason.
Ref.1 - Spare plate Code
1079 9903 48
8.2 POSITION OF THE DATA PLATES (Fig. 4)
Ref. 2) “IN”
Ref. 4) Identification plate
Ref. 3) “OUT”
9.0 DRYERS ROOM
9.1 FLOOR
The floor must be even and of industrial type; the total weight of the machine is shown in Fig. 5
Remember the total weight of the machine when positioning it.
9.2 VENTILATION
The choice of an appropriate room will prolong the life of your dryer; the room must be spacious, dry, well ventilated and
free from dust.
The operating conditions to be complied with are the following:
Min. room temperature:
+ 5 °C (41 °F)
(compulsory)
Min. inlet allowed temperature:
+3 °C (37,4 °F)
Max. room temperature:
+ 45 °C (113 °F)
(compulsory)
Max. inlet allowed temperature:
55 °C (131 °F)
Max. temperature of incoming air:
55 °C (131 °F)
Max. working pressure:
13 bar (188 °F)
10.0 TRANSPORT AND HANDLING
The machine must be transported as shown in the following figures.
11.0 UNPACKING
CUTTING THE METAL STRAPPING IS A DANGEROUS OPERATION, DO NOT ABANDON THE CUT PIECES IN THE ENVIRONMENT.
After removing the packing, ensure that the machine is unbroken and that there are no visibly damaged parts.
If you are in doubt, do not use the machine but apply to the manufacturer technical assistance service or to your dealer.
The packing material (plastic bags, polystyrene foam, nails, screws, wood, metal strapping, etc.) must not be left within
the reach of children or abandoned in the environment, as they are a potential source of danger and pollution.Dispose of
these materials in the approved collection centres.
FIG. 5
MODD.
NET
WEIGHT
Kg. (lb)
QPNC1600
380 (837)
QPNC1800
550 (1212)
QPNC2500
600 (1323)
QPNC3000
650 (1433)
FIG. 4
1
1079 9903 48
1
4
2
3
1
4
2
3