Section IX - Technical data
Quincy Compressor
99
10 bar compressors, 50 Hz
Compressor type
QOF 20
QOF 22
QOF 30
Maximum working pressure (compressors
without integrated dryer)
bar(e)
10
10
10
Maximum working pressure (compressors
without integrated dryer)
psi(g)
145
145
145
Maximum working pressure (compressors with
integrated dryer)
bar(e)
9.75
9.75
9.75
Maximum working pressure (compressors with
integrated dryer)
psi(g)
141
141
141
Reference working pressure (compressors
without integrated dryer)
bar(e)
9
9
9
Reference working pressure (compressors
without integrated dryer)
psi(g)
130.5
130.5
130.5
Reference working pressure (compressors with
integrated dryer)
bar(e)
8.75
8.75
8.75
Reference working pressure (compressors with
integrated dryer)
psi(g)
127
127
127
Air temperature at outlet valve (compressors
without integrated dryer)
°C
32
30
30
Air temperature at outlet valve (compressors
without integrated dryer)
°F
90
86
86
Air temperature at outlet valve (compressors
with integrated dryer)
°C
25
30
55
Air temperature at outlet valve (compressors
with integrated dryer)
°F
77
86
131
Motor shaft speed
rpm
2900
2900
2900
Nominal motor power
kW
4 x 3.7
3 x 5.5
4 x 5.5
Nominal motor power
hp
4 x 5
3 x 7.5
4 x 7.5
Sound pressure level (compressors without
integrated dryer)
dB(A)
63
64
65
Refrigerant type (compressors with integrated
dryer)
R404a
R404a
R404a
Dew point (compressors with integrated dryer)
°C
4
4
4
Dew point (compressors with integrated dryer)
°F
39
39
39
116 psi compressors, 60 Hz
Compressor type
QOF 20
QOF 22
QOF 30
Maximum working pressure (compressors
without integrated dryer)
bar(e)
8
8
8
Maximum working pressure (compressors
without integrated dryer)
psi(g)
116
116
116
Maximum working pressure (compressors with
integrated dryer)
bar(e)
7.75
7.75
7.75
Содержание QOF 20