background image

Quincy Compressor

1312100602, September 2012 

3501 Wisman Lane, Quincy IL - 62305-3116

TABLE OF CONTENTS

SAFETY ....................................................................1
DESCRIPTION & APPLICATION .............................2
INSTALLATION .........................................................2
SYSTEM COMPONENTS .........................................4
PRE-STARTING CHECKLIST ..................................6
STARTING & STOPPING THE COMPRESSOR ......6
MAINTENANCE ........................................................6
TROUBLESHOOTING ..............................................9
COMPRESSOR UNIT PARTS ................................13
DECALS & DIMENSIONS ......................................15

SAFETY

“ D A N G E R ! ”,   “ WA R N I N G ! ”,   a n d  “ C AU T I O N ! ”  

are displayed in large bold capital letters to call 

attention to areas of vital concern. They represent 

different degrees of hazard seriousness, as stated by 

the following:

DANGER !

Immediate hazards which will re sult in severe per-
sonal injury or death.

WARNING !

Hazards or unsafe practices that could result in 
personal injury or death.

CAUTION !

Hazards or unsafe practices which could result in 
minor personal in 

jury, product or property dam-

age. 

 WARRANTY

Quincy Compressor Reciprocating Products 

                 

 Single Stage Compressors

What does this warranty cover?

Quincy Compressor (the Company) warrants this compressor to be free from defects in materials and workmanship for a period of one 

year from date of purchase.

What are the Company's obligations under this warranty?

In the event this compressor proves to be defective during the warranty period, the Company will, at its sole option, either repair or 

replace this compressor.  The Company and its authorized agents may use, at their discretion, reconditioned units when undertaking 

such repairs or replacement.  Repaired or replacement units shall be warranted hereunder for the remainder of the warranty period 

applicable to the original compressor, or ninety (90) days, whichever is greater.

How do you get service?

Contact your local Quincy distributor, or call the Company's Service department at (217) 222-7700, for directions to the nearest autho-

rized warranty repair center.  In order for you to be eligible to utilize this warranty, Company must have received a completed warranty 

registration card within thirty (30) days of your purchase of this compressor or, at the time service is requested, you must be prepared 

to provide proof of purchase in the form of a receipt or invoice.  All moving, shipping and insurance charges incurred by you to deliver 

this compressor to the nearest authorized warranty repair center shall be paid by you and shall be your exclusive responsibility.  All 

risk of loss or damage to your compressor in transit shall remain with you until such time as Company or its authorized agents take 

receipt of your compressor.

What does this warranty not cover?

This warranty is contigent upon proper use of the compressor by purchaser and does not cover:

(A) Abnormal conditions, accident, neglect, misuse or improper storage of the unit.
(B) Deviation from operating or maintenance instructions.
(C) Modifications not authorized by the Company.
(D) Repairs or maintenance (other than routine air tank draining and air filter changes required by your operating and maintenance 

manual) made by persons other than Company or its authorized agents.

What are the limits of Company's Liability?

The warranty given herein, together with any implied warranties covering this compressor, including warranties of merchantability or 

fitness for a particular purpose are limited in duration to one year from the date of purchase, and no warranties, whether express or 

implied will apply after this period.  Some states and provinces do not allow limitations on how long an implied warranty lasts, so the 

above limitations may not apply to you.

If this compressor is not in good working order as warranted above, your sole remedy shall be repair or replacement as provided above.  

In no event will Company be liable to you for any damages, including any lost profits, lost savings or other incidental or consequential 

damages arising out of the use or inability to use such compressor, even if Company or your place of purchase has been advised of the 

possibility of such damages.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state or province to province.

Содержание Q12120P

Страница 1: ...ation and must be carefully read in its entirety and understood prior to installation by all personnel who install operate and or maintain this product Manual No 1312100602 September 2012 Edition Single Stage Compressors Instruction Parts Manual ...

Страница 2: ... thirty 30 days of your purchase of this compressor or at the time service is requested you must be prepared to provide proof of purchase in the form of a receipt or invoice All moving shipping and insurance charges incurred by you to deliver this compressor to the nearest authorized warranty repair center shall be paid by you and shall be your exclusive responsibility All risk of loss or damage t...

Страница 3: ...ompressor unit sold by Quincy Compressor is hereby warned that failure to ob serve the safety precautions and proce dures outlined in this manual may result in serious personal injury damage to property and may void your warranty Quincy Compressor must authorize all warranty service Before contacting your distributor or the factory check the maintenance requirements and the troubleshooting guide f...

Страница 4: ...elay will stop the unit if the motor becomes overheated Causes for overheating of the motor can be found in TROUBLESHOOTING Once the overload relay has been tripped the motor must cool and the red overload button on the motor must be reset be fore the unit will start CAUTION Overload relays are designed to protect the motor from damage due to motor overload If the overload relaytripspersistently D...

Страница 5: ...lve allows the operator to control the air pressure setting of the compressor discharge A gauge is provided to indi cate the air pressure Pressure Relief Valves Pressure relief valves aid in preventing system fail ures by relieving system pressure when com pressed air reaches a predetermined pressure level All air receivers must be equipped with an adequately sized pressure relief valve This type ...

Страница 6: ...ING Oil and moisture residue must be drained from the air receiver daily or after each use Accumulations of oil residue in the receiver can be ignited by em bers of carbon created by the heat of compression causinganexplosion damagetopropertyandinjury to personnel WARNING Follow ASME code for air receiver tanks and other pressurecontainingvessels Pressurevesselsmust not be mod ified welded on or r...

Страница 7: ... Lubrication Step 2 Make sure all pressure relief valves are cor rectly installed Refer to SYSTEM COMPO NENTS Step 3 Be sure all guards are in place and securely mounted Refer to SYSTEM COMPO NENTS Step 4 Check all hoses and fittings for weak or worn conditions and replace if necessary Step 5 Check fuses circuit breakers and overload relays for proper sizes Step 6 Open the tank drain valve in the ...

Страница 8: ...t relieving the system pressure Give compressor overall visual inspection and be sure safety guards are in place Check for any unusual noise or vibration Weekly Pull on the ring of the pressure relief valves to make sure they are operating correctly Air pressure should escape when the ring is pulled refer to Fig 3 Check all pressurized components for rust crack ing or leaking Immediately discontin...

Страница 9: ...st be removed Prior to re moving the belt guard follow the procedures outlined under MAINTENANCE Check the belt alignment by placing a straightedge against the face of the flywheel touching its rim at two places refer to Fig 6 Adjust the flywheel or motor pul ley so that the belt runs parallel to the straightedge Use a wheel puller to move the motor pulley on the shaft Fig 7 Typical Belt Adjustmen...

Страница 10: ... from circuit being used 3 Replace check valve or un loader 4 Check with voltmeter 5 Replace with correctly sized motor 6 Check for proper size fuse 7 Replace motor 8 Change power cord voltage of motor to match voltage of power source PROBLEM CAUSES CORRECTION 1 Plug power cord in 2 Switch to auto 3 Turn OFF AUTO switch to the OFF po sition Push the motor thermal over load red button firmly until ...

Страница 11: ...Replace motor 12 Move the compressor to a well ven tilated area 13 Change power cord voltage of motor to match voltage of power source PROBLEM CAUSES CORRECTION 1 Realign or tighten pulley and fly wheel 2 Take to Authorized Service Center 3 Tighten belt refer to Belt Align ment Adjustment 4 Shim to level surface fasten to floor if possible 1 Pulley flywheel misaligned or loose 2 Bent crankshaft 3 ...

Страница 12: ...ulty regulator 11 Insufficient pressure at tool or acces sory 1 Contact qualified electrician 1 Reversed wiring polarity 10 Compressor runs backwards 1 Change lubricant Move compressor or air inlet to less humid atmosphere 1 Water in lubricant due to humidity or condensation 9 Crankcase lubricant is milky 1 Take to Authorized Service Center 1 Damaged inlet reed valve 8 Air blowing from inlet filte...

Страница 13: ...ore head valves fail ing to seat properly 7 Damaged cylinder head gas ket 8 Restriction in head or check valve 15 Compressor overheats 1 Replace defective pressure switch 2 Limit the air pressure to the com pressor s capacity Either use a smaller tool or a larger compressor 1 Defective pressure switch 2 Compressor incorrectly sized 14 Compressor unit runs continu ously 1 Drain tank after every use...

Страница 14: ...itch Regulator Valve Cord Rubber Foot Pressure Gauge Tank Wheel Motor Valve Plate Drain Valve Check Valve i S T l S Parts List QTY PART NUMBER DESCRIPTION 1 1312100119 B2800 Compressor 1 6229024900 Valve Plate 1 1312100388 Motor 1 1312100603 Tank 1 1312100170 Check Valve 1 1312100455 Pressure Switch 1 1312100005 Relief Valve 2 1312100006 Pressure Guage 1 1312100213 Discharge Tube 1 6229020500 Air ...

Страница 15: ...00123 B3800 Compressor 1 6229024900 Valve Plate 1 1312100390 Motor 1 1312100604 Tank 1 1312100170 Check Valve 1 1312100455 Pressure Switch 1 1312100005 Relief Valve 1 1312100028 Pressure Guage 1 1312100207 Discharge Tube 1 6229020500 Air Filter Kit 1 1312100360 Drain Valve 1 6214343100 Belt Guard Front 1 2236110472 Belt Guard Back 1 1312100442 Drive Pulley 1 1312100134 Drive Belt 1 1312100162 Ball...

Страница 16: ...Quincy Compressor 1312100602 September 2012 15 3501 Wisman Lane Quincy IL 62305 3116 DECALS AND DIMENSIONS Model Q12120P Model Q12126VP ...

Страница 17: ...Quincy Compressor 1312100602 September 2012 16 3501 Wisman Lane Quincy IL 62305 3116 Model Q13160V ...

Страница 18: ...rty 30 days after receipt of notification of readiness for shipment Claims for shortages will be deemed to have been waived if not made in writing with ten 10 days after the receipt of the material in respect of which any such shortage is claimed Seller is not responsible for loss or damage in transit after having received In Good Order receipt from the carrier All claims for loss or damage in tra...

Отзывы: