9
E
N
G
L
I
S
H
MAINTENANCE
Actuators need very little maintenance; however their function depends also on the gate conditions,
hence here are operations to be done to keep the gate efficient at all times.
Warning: no one but the maintenance man, who must be a specialized technician, must be able to
control the automatic gate while it is being serviced. For this reason please turn off electricity,
avoiding also electric shocks hazard. If on the contrary electricity must be on for certain checks,
remember to check or disable any control device (remote controls, push button panels etc.) except
the one used by the service man.
Routine maintenance
Each of the following operations must be done when needed and in all cases at least every 6 months:
1) Mechanical maintenance
-
Lubricate (with oilier) the hinges on which the gate swings;
-
check the good conditions of brackets and motor’s hinges;
-
do an unlocking operation to be sure the mechanism is always efficient.
2) Electrical maintenance
-
Check the proper working of the safety devices;
-
check the electronic friction’s efficacy;
-
check the earth system’s (differential’s) efficacy. Try the differential switcher once a month
by pushing the special test button on the switcher.
E
N
G
L
I
S
H