5 of 12
Stand By
The gate is completely closed and the safety devices are unactivated. The control board is ready to start a working
cycle. In this state the flashing lamp is off.
Opening
The gate is opening and the flashing lamp blinks quickly.
Pause
During pause the motor is stopped and the flashing lamp is on.
After pause time has expired (
F0
) the gate starts closing.
Closing
The gate is closing and the flashing lamp blinks slowly.
Stop
opening
The gate has been stopped while it was opening. A new start command begins the closing phase.
In this state the flashing lamp is off.
Stop
closing
The gate has been stopped while it was closing. A new start command begins the opening phase.
In this state the flashing lamp is off.
Types of
Input
There are two types of input: external and remote control. The external inputs are all devices (photocells, normally
closed contacts and normally open contacts) wired to the terminal blocks. Each input is programmable with a
function. The
safety functions
match the normally closed contacts. The other functions match the normally open
contacts. The
safety functions
are:
stop
,
internal photocell,
external photocell, opening limit switches N.C.
and
closing limit switches N.C.
The other functions are:
start
,
pedestrian start, opening limit switches N.O.
and
closing limit switches N.O.
The functions of terminal block inputs are configurable by parameters
E1
,
E2
,
E3
,
E4
,
E5
,
E6
and
E7
.
A remote control input is programmable as:
start
,
stop
,
pedestrian start
and
fast closure start
. The remote
controls are configurable by parameters
r1
,
r2
,
r3
,
r4
.
The control board doesn't distinguish between the type of input but only between the functions.
Input Is
activated
An input is activated when its state changes from the standard state. For instance, a photocell is activated when
the beam from the transmitter to the receiver is interrupted. While a generic push-button or a remote key is
activated only when it is pushed down.
All these actions are recognized by the control board which shows these changes on the display.
When more inputs are activated at the same time the display shows only the most important input. The order
from the most important to the least important input is:
stop
5t
,
internal and external photocells
FH
,
external
photocells
tC
,
internal photocells
tA
,
start
Go
,
pedestrian
start
PE
,
open
only
oP
,
close only
CL
,
Opening and Closing limit switches
1H
,
Closing limit switch N.C.
FC
,
Opening limit switch N.C.
FA
,
Closing
limit switch N.O.
LC
,
Opening limit switch N.O.
LA
.
Start
commands
The
start commands
are:
start
,
pedestrian
start,
open
and
fast closure
start
. They are able to start a working
cycle. The function of start commands depend on
F5
and
F6
parameters programming.
To know more see
F5
and
F6
description.
To know how the fast closure start command works see
r4
description.
To know how the start command works see
Standard Working Cycle
.
To know how the pedestrian start command works see
Pedestrian Working Cycle
.
Safety
commands
The
safety commands
are:
stop
,
internal photocell
and
external photocell
.
The stop commands always stop the gate. Instead the functions of photocells depend on
F8
parameter
programming. To know more see
F8
description.
Standard
working
cycle
A
standard working cycle
begins when an input programmed as
start
,
open
or
fast closure
is activated and the
control board is in
stand by
.
The
motor
works for a total time of
A1
plus
A2
seconds during the opening and the closing
.
When a standard
working cycle is in progress, the
pedestrian start
commands are considered as a
start
. The
working cycle
is
finished when the control board returns to stand by state. This functionality can be handled by parameters
programming. The
working cycle
finishes when the control board returns to
stand by
. This functionality can be
handled by parameters
F0
,
F5
,
F6
.
Pedestrian
working
cycle
A
pedestrian working cycle
begins when a
pedestrian
start
is activated and the control board is in stand by.
The
motor
works for a total time of
F1
seconds during the opening and closing. The slowdown phase is skipped
during the opening and executed during the closing. The slowdown time is automatically managed by the control
board during a pedestrian working cycle. When a pedestrian working cycle is in progress, the start commands are
considered as a pedestrian start. The working cycle is finished when the control board returns to stand by state.
GLOSSARY