![quiko QK-CE220RL4 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/quiko/qk-ce220rl4/qk-ce220rl4_user-manual_773428003.webp)
BUTTONS
@
A
Scrolls menu from
A1
to
P2
@
B
Scrolls menu from
P2
to
A1
@
C
Increases value or set
SI
(
means: ON or ENABLED).
@
D
Decreases value or set
no
(
means: OFF or DISABLED).
Terminal Block Settings
DISPLAY DEFAULT
@
C
@
D
DESCRIPTION
E1
Go
↓
↑
no
=
Disabled.
Go
=
Start
N.O
.
oP
=
Open only
N.O
.
CL
=
Close only
N.O
.
E2
no
↓
↑
no
=
Disabled.
St
=
Stop
N.C
.
E3
no
↓
↑
no
=
Disabled.
tC
=
External photocell
N.C
.
E4
no
↓
↑
no
=
Disabled.
tA
=
Internal photocell
N.C
.
E5
FC
↓
↑
no
=
Disabled.
FC
=
Closing limit switch
N.C
.
LC
=
Closing limit switch
N.O
.
E6
FA
↓
↑
no
=
Disabled.
FA
=
Opening limit switch
N.C
.
LA
=
Opening limit switch
N.O
.
E7
PE
↓
↑
no
=
Disabled.
PE
=
Pedestrian
N.O
.
oP
=
Open only
N.O
.
CL
=
Close only
N.O
.
N.O. → Normally Open N.C. → Normally Closed
2 of 12
INPUT/OUTPUT CONNECTIONS
FUNCTION SUMMARY
Display Report
St
Stop.
FH
External pho
Internal photocell.
tC
External photocell.
tA
Internal photocell.
oP
Open Only.
CL
Close Only.
1H
Opening limit
Closing limit switch.
FA
Opening limit switch.
Normally Closed.
FC
Closing limit switch.
Normally Closed.
LA
Opening limit switch.
Normally Open.
LC
Closing limit switch.
Normally Open.
L2
Recovery Loop is
running.
-
Remote key is
pressed.
1t
Photocells test error.
7A
Motor has detected
an obstacle during the
standard working
time.
8A
Motor has detected
an obstacle during the
slowdown working
time.
9A
Motor is in thermal
protection state.
FF
The radio memory is
full.
Motor Setting
DISPLAY DEFAULT
@
C
MAX
@
D
MIN
DESCRIPTION
A1
30
sec
99
sec
00
sec
Standard working time
A2
10
sec
99
sec
00
sec
Slowdown working time
A3
0.1
sec
1.5
sec
0.1
sec
Start up time
A5
7
10
1
Standard force
A6
8
10
1
Slowdown force
A7
NO
(DISABLED)
99 - NO
0
Standard obstacle
detection threshold.
During opening and
closing, for the standard
working time, the display
shows the motor stress.
A8
NO
(DISABLED)
99 - NO
0
Slowdown obstacle
detection threshold.
During opening and
closing, for the slowdown
working time, the display
shows the motor stress.
General Functions
DISPLAY DEFAULT
@
C
MAX
@
D
MIN
DESCRIPTION
F0
10
sec
99
sec
00
sec
Pause time.
To disable hold down
@
C
button until display shows
5t
F1
7
sec
A1
sec
0
sec
Pedestrian working time.
It is the motor working
time during a pedestrian
working cycle.
F2
0.0
sec
1.0
sec
0.0
sec
Kick back function during
closing.
F3
0.0
sec
5.0
sec
00
sec
Pre-blinking time
F4
NO
(OFF)
SI
(ON)
NO
(OFF)
Kick back function during
opening.
F5
NO
(OFF)
SI
(ON)
NO
(OFF)
Step-by-step function
F6
NO
(OFF)
SI
(ON)
NO
(OFF)
Community mode
F8
SI
SI
NO
Photocells logic:
SI
→
Standard logic
no
→
Reverse logic
L1
00
min
10
min
00
min
Cold winter function. This
function is useful in
countries where the
winter is extremely cold.
L2
NO
(OFF)
SI
(ON)
NO
(OFF)
Recovery loop function
.
This function is useful to
avoid motor lock due to
gate inertia.
t1
NO
(OFF)
SI
(ON)
NO
(OFF)
Photocells test
t2
SI
(ON)
SI
(ON)
NO
(OFF)
Motor thermal protection
test
Courtesy Functions
DISPLAY
DISPLAY
@
C
DESCRIPTION
d0
no
Set Up
To restore default setting hold
down
@
C
button until display
shows
--
P1
__
X
When a start command is
received the control board
starts an automatic procedure
to acquire the gate working
times.
Radio Functions
DISPLAY
DISPLAY
@
C
DESCRIPTION
r0
1
...
2
...
Delete
To erase a code:
Hold down
@
C
button on the
selected
code until the display
turns off
**
r1
=_
Save
To save a remote key:
Hold down a remote key. When
the display shows
_
,
push
down
@
C
b
utton on the control
board.
The control board holds up
to 99 codes.
r1
→
Start
r2
→
Stop
r3
→
Pedestrian start
r4
→
Fast closure start
r2
=_
Save
r3
=_
Save
r4
=_
Save
r5
no
Delete
To erase all codes:
Hold down
@
C
button
until
display
stops flashing
SI