ALL DIP-SWITCH:

FEATURES

The control unit 

QK-CE220CN

 control equipment for sliding systems and road barriers to 230Vac power supply.

This panel can manage motors with or without limit switches, encoders and limitswitches.

The peculiarity of 

QK-CE220CN

 is that it has separate torque control, through trimmer T1 and T2 (T1 regulates the torque while

running in normal speed the T2 adjusts the torque during deceleration)

. Interacting on these devices can optimize the operation of

the automation so as to be within the actual rules. The programming of the switches and remote controls is self-learning, so everything
is easier.

In case management through ENCODER (DIP 8 ON) security will be guaranteed by the photocells/bands safety or to torque
control: if the gate find an obstacle will be reversed or blocked.
With ENCODER not active (OFF DIP 8)

 not have the reverse function but only torque control through

trimmer

T1

 and

T2.

PROGRAMMING REMOTE CONTROL

The control unit is able to handle radio fixed code and rolling code. The two systems can not be managed simultaneously, but
with the first remote control will be programmed encoding system.

The 

QK-CE220CN

 can handle 254 transmitters ROLLING CODE.

The programming of the transmitters is done by pressing the

P1 for 2sec

, the LED L2 turns on, then pressing the button of the remote

will flash twice to indicate the LED L2 is stored in memory. After 6 seconds automatically central will exit the programming function.

PROGRAMMING PEDESTRIAN MODE (by remote control)

To program this function push

P1 button for 2sec

,

 release it and press it again for 1 sec

, the LED L2 starts flashing and each press

of the button on a remote control will be a rapid double flash of the LED L2, after 6sec the control board automatically exit to
programming.

The operating time of the pedestrian mode is 8 sec.

REMOVE ALL CODES

Press and hold the

P1 for 6

seconds when it is released there will be a quick flash of the LED L2, with consequent turning off after 6

seconds.

PROGRAMMING THE STROKE

The programming begins automation is closed, the first operation will be the opening, otherwise reverse the direction by

DIP switch 4.

PROGRAMMING with slow down (DIP 7ON)

To enter in programming, press the P2 button for 2 seconds, the LED3 will flash

Give a

FIRST PULSE by START

 contact (terminals 1 and 2) or by transmitter already been programmed.

The operator will start the opening phase, give a

SECOND PULSE

 where you want to start the slow down in opening.

The engine will complete the stroke and will stop at close limitswitch (if you chose an automatism without limitswitches must give a
further impulse to fix the stopping point of the stroke).

If you choose to have the AUTOMATIC CLOSING (OPTION 2 IN ON), the closing time will be calculated from the moment when
the operator arrives to open limitswitch until you give the THIRD PULSE, the automatism will start closure.

Where do you want start slowing down in closing you must give the

FOURTH PULSE.

 The arrest will be through the closing limitswitch

and now the LED will turn off 3. If the automatism is not expected to limit switch, you will need to give a last pulse where you want
to stop.

PROGRAMMING without slow down (DIP 7OFF)

Set the option 7 to OFF for the exclusion of the slowdown phase. Follow the procedure listed above (learning with slowdown) without
transmitting the second pulse in opening and the fourth during closing. So once impulses transmitted to the beginning of the maneuvers,
in opening and in closing, they will finish at the limitswitch position.

OPERATION LOGIC OF THE SAFETY

SAFETY BAND TERMINAL (4-6)

   This contact protects opening and closing.

  

DIP 5 ON: in opening when there is an obstacle, the engine stop and reverse for 2 sec.

  

DIP 5 OFF: in opening when there is an obstacle engine STOP

  

In both cases in closing when there there is an obstacle the gate stop.

PHOTOCELLS TERMINAL (5-6)

    This contact protects only in closing

  

In closing when there is an obstacle engine STOP

STOP TERMINAL (18-19)

 

      

The contact if open will cause the immediate arrest of the automation in any situation.

FLASHING OPERATION WITH DIP6 ON

IN OPENING:

Flash slow

IN CLOSING:

Flash fast

IN PAUSE:

Steady light

PHOTOCELL ENGAGED:

Turn off

DIP 1

COUNTERWEIGHT DOORS/SLIDING GATE

Counterweight doors function
Sliding gate function

DIP 2

AUTOMATIC CLOSING

Automatic closing activated
Automatic closing not actived

DIP 3

CONDOMINIUM / STEP BY STEP

The automation will end the operation always on end
switches, in opening does not accept pulses, in closing a
pulse will cause the reverse.
For each pulse automation will stop
(OPEN-STOP-CLOSE-STOP)

DIP 4

INVERSION OF THE DIRECTION

Invert direction and the limitswitch
Invert direction and the limitswitch

DIP 5

SETTING SEFETY CONTACT IN OPENING

In opening the control board stop and invert for 2sec the
gate direction
In opening the control board stop the gate direction

DIP 6

FLASHING FUNCTION

Intermittent light
Steady light

DIP 7

SLOW DOWN

Activate
Not activate

DIP 8

ENCODER

Encoder actived
Encoder not actived

DIP 9

OPEN RADIO MEMORY WITH TRANSMITTER

With  you can storable other transmitter without open the

control board.

          Actived

Not actived

DIP

10

MANAGE SLOWDOWN

Heavy leaf
Light leaf

ON-

OFF-

ON-

OFF-

ON-

OFF-

ON-

OFF-

ON-

OFF-

ON-

OFF-

ON-

OFF-

ON-

OFF-

ON-

OFF-

ON-

OFF-

www.quikoitaly.com

QUIKO ITALY

VIA SECCALEGNO, 19

36040 SOSSANO (VI) ITALY

TEL: +39 0444 785513

EMAIL: [email protected]

Содержание QK-CE220CN

Страница 1: ...ity during the maneuver TRIMMER T2 The trimmer POWER SLOW regulates the torque and sensitivity during SLOW DOWN phase The TORQUE increases turning the trimmer in clockwise sense L1 Led STATUS Lit when the unit is powered L2 Led RADIO Lit when accessing in radio storage L3 Led PROG TIME It is blinking when in programming L4 Led START Lit when taking a pulse L5 Led PEDESTRIAN Lit when taking a pedes...

Страница 2: ...itches must give a further impulse to fix the stopping point of the stroke If you choose to have the AUTOMATIC CLOSING OPTION 2 IN ON the closing time will be calculated from the moment when the operator arrives to open limitswitch until you give the THIRD PULSE the automatism will start closure Where do you want start slowing down in closing you must give the FOURTH PULSE The arrest will be throu...

Страница 3: ...8com NC Contact FIN DE COURSE FERMETURE 11 12 24V Tension photocellules accessoires 24VAC 250mA 13 14 15 230V Entrée MOTEUR 13 14 entrée phases avec condensateur en paralléle 15 neutre commun 16 18 230V Entrée FEU CLIGNOTANT 17 18 230V Entrée LUMIÉRE DE COURTOISIE 19 20 230V Entrée LIGNE 230VAC 21 22 TERRE 23 24 Entrée ANTENNE 23 joiner 24 signal L1 Led STATUS Allumé quand l unité de commande est ...

Страница 4: ...matisme sans FC donnez une impulsion pour arrêter la manœuvre 8 Quand la led 3éteinte vousterminéprogrammation PROGRAMMATION SANS RALENTISSEMENT OPTION 7 OFF Réglez l option 7 sur OFF exclusionralentissement Suivezprocédure décrite précédemment programmation avec ralentissement sans transmettredeuxième impulsion pour éliminationdu ralentissementmanœuvre d ouverture e le quatrième impulsion élimina...

Страница 5: ... Trimmer Power regola la coppia e la sensibilità in manovra TRIMMER T2 Il Trimmer Power Slow regola la coppia e la sensibilità in fase di rallentamento La coppia aumenta ruotando il trimmer in senso orario L1 Led STATO Acceso quando la centrale è alimentata L2 Led RADIO Acceso quando si accede in memoria radio L3 Led PROG TEMPI Acceso lampeggiante in programmazione L4 Led START Acceso quando si dà...

Страница 6: ...verrà calcolato dal momento in cui l automatismo sarà arrivato ad impegnare il finecorsa di apertura attendere il tempo di pausa desiderato dare un TERZO IMPULSO l automatismo inizierà la fase di chiusura dare quindi un QUARTO IMPULSO nel punto i cui si desidera iniziare il rallentamento in chiusura L arresto avverrà tramite il finecorsa di chiusura e a questo punto si spegnerà il LED 3 Nel caso i...

Страница 7: ...cienden a la vez cuando actúa la parada de emergencia STOP L9 Led FOT AP Borde de seguridad Se enciende siempre que esté cerrado el contacto de la fotocélula AP Borde de seguridad 230V AC 10 550 W 24V AC 250mA 5 a 120 sec 3 a 120 sec 2 a 120 sec 180 sec 254 codici Código fijo Roll code 433 92 868 Mhz 20 a 70 C Mejor de 100dBm Conf ETS 300 220 ETS 300 683 CARACTERÍSTICAS TÉCNICAS Alimentación Poten...

Страница 8: ...automatización sin final de carrera se debe dar un nuevo impulso para fijar el punto de la carrera de parada Si usted decide tener el CIERRE AUTOMÁTICO DIP2 ON el tiempo de cierre se calcula desde el momento que el final de carrera en abertura es ocupado esperar el tiempo de pausa deseado y pulsar el mandos para iniciar el cierre Cuando quiera que inicia el paro suave en cierre pulso el boton del ...

Отзывы: