Technical Information

Service Manual

1. Select  the  installation  location  according  to  the  require-

ment  of  this  manual.(See  the  requirements  in  installation 

part)

2. Handle unit transportation with care; the unit should not 

be carried by only one person if it is more than 44lb.

3. When installing the indoor unit and outdoor unit, a suffi-

cient fixing bolt must be installed; make sure the installation 

support is firm.

4. Ware safety belt if the height of working is above 6.6ft.

5. Use equipped components or appointed components dur-

ing installation.

6. Make sure no foreign objects are left in the unit after fin-

ishing installation.

Electrical Safety Precautions:

7. Notes for Installation and Maintenance

Safety Precautions: 

Important!

Please read the safety precautions carefully before instal-

lation and maintenance.

The following contents are very important for installation 

and maintenance.

Please follow the instructions below.

●The installation or maintenance must accord with the 

instructions.

●Comply with all national electrical codes and local 

electrical codes.

●Pay attention to the warnings and cautions in this 

manual.

●All installation and maintenance shall be performed by 

distributor or qualified person.

●All electric work must be performed by a licensed 

technician according to local regulations and the 

instructions given in this manual.

●Be caution during installation and maintenance. Prohibit 

incorrect operation to prevent electric shock, casualty and 

other accidents.

1.  Cut  off  the  power  supply  of  air  conditioner  before 

checking and maintenance.

2.  The  air  condition  must  apply  specialized  circuit  and 

prohibit share the same circuit with other appliances.

3.  The  air  conditioner  should  be  installed in  suitable 

location and ensure the power plug is touchable.

4.  Make  sure  each  wiring  terminal is  connected firmly 

during installation and maintenance.

5.  Have  the  unit  adequately  grounded.  The  grounding 

wire can’t be used for other purposes.

6. Must apply protective accessories such as protective 

boards, cable-cross loop and wire clip.

7.  The  live  wire,  neutral  wire  and  grounding  wire  of 

power  supply  must  be  corresponding  to  the  live  wire, 

neutral wire and grounding wire of the air conditioner.  

8. The power cord and power connection wires can’t be 

pressed by hard objects.

9. If power cord or connection wire is broken, it must be 

replaced by a qualified person.

Warnings

Improper installation may lead to fire hazard, explosion, 

electric shock or injury.

Installation Safety Precautions:

Part 

: Installation and Maintenance 

10. If the power cord or connection wire is not long enough, 

please  get  the  specialized power  cord  or  connection  wire 

from the manufacture or distributor. Prohibit prolong the wire 

by yourself.

11.  For  the  air  conditioner  without  plug,  an  air  switch  must 

be  installed in  the  circuit.  The  air  switch should  be  all-pole 

parting and the contact parting distance should be more than 

3mm.

12. Make sure all wires and pipes are connected properly and 

the valves are opened before energizing.

13. Check if there is electric leakage on the unit body. If yes, 

please eliminate the electric leakage.

14. Replace the fuse with a new one of the same specification 

if  it  is  burnt  down;  don’t  replace  it  with  a  cooper  wire  or 

conducting wire.

15. If the unit is to be installed in a humid place, the circuit 

breaker must be installed.

Содержание QS09-VJ115

Страница 1: ...QS09 VJ115 QS12 VJ115 QS09 VP115 QS12 VP115 Refrigerant R410A Model INSTALLATION MANUAL...

Страница 2: ...condition must apply specialized circuit and prohibit share the same circuit with other appliances 3 The air conditioner should be installed in suitable location and ensure the power plug is touchabl...

Страница 3: ...ng tape 4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill drill head electric drill 6 T...

Страница 4: ...east 0 5ft At least 0 5ft At least 0 5ft At least 8 2ft Space to the wall S p a c e t o t h e o b s t r u c t i o n r o o l f e h t o t e c a p S Space to the obstruction Drainage pipe Space to the wa...

Страница 5: ...or unit Make the bound pipes pass through the wall hole and then connect outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installat...

Страница 6: ...ditioner is grounding wire which can t be used for other purposes 3 The grounding resistance should comply with national electric safety regulations 4 The appliance must be positioned so that the plug...

Страница 7: ...e the torque wrench on the union nut Tighten the union nut with torque wrench As show in Fig 6 4 Wrap the indoor pipe and joint of connection pipe with insulating pipe and then wrap it with tape As sh...

Страница 8: ...ower connection wire go through the cable cross hole at the back of indoor unit and then pull it out from the front side As show in Fig 12 3 Remove the wire clip connect the power connection wire to t...

Страница 9: ...ve the cable crossing board 2 of right side plate for outdoor unit 2 Remove the wire clamps pass the power connection cord and power cord through the cable crossing board 1 to connect the terminal The...

Страница 10: ...Remove the valve caps on the liquid valve and gas valve and the nut of refrigerant charging vent 2 Connect the charging hose of piezometer to the refrigerant charging vent of gas valve and then conne...