2.2  Flow Hood

1.  Expand flow hood by inserting the 4 flexible poles into the inside corners of the hood area

a.  There are socket holes in each corner (top and bottom) for poles to slide into

2.  Insert adjustable poles into rotating pvc knuckle

3.  Stand up hood and adjust poles to get hood flush with the ceiling.

    

IMPORTANT:

 Make sure no canned lights, vents or openings of any  

    kind are on ceiling area within the flow hood. If there are, tape them  

    off completely or test may yield inaccurate results.

4.  Ensure hood is flush by lightly pushing up on bottom of hood.

a.  If you see the top of hood move, readjust poles by going higher.

b.  Check again and repeat if necessary, until top of hood is flush with 

ceiling.

2.3  Connecting Flow Hood to Base Stand

1.  Slide Base Stand with fan directly under the 

flow hood

2.  Pull transition duct around the blower door 

fan and work the drawstring around the fan. 

Pull drawstring towards the middle of fan 

housing to ensure no openings are present 

between the fan housing and the transition 

duct

a.  If necessary, fold and overlap 

transition duct and pull drawstring 

tight

Содержание WHF-PFH

Страница 1: ...OPERATION MANUAL HERS POWERED FLOW HOOD MODEL WHF PFH MAKERS OF THE QUIETCOOL ADVANCED WHOLE HOUSE FAN...

Страница 2: ...ce personnel should service the system The user should not attempt to service the product 6 Maneuvering the Unit When lifting stand or moving the unit around the house be very careful not to drag it a...

Страница 3: ...Velcro iv Coroplast rectangular cutout v Soft plastic tubing with 4 barbed tee fittings pressure taps vi Fiberglass poles QTY 4 Bottom square Frame 27 5 x 27 5 Top Octagonal Frame Telescoping Legs i 4...

Страница 4: ...Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not place this equipment or power cord in water or other liquid Use only t...

Страница 5: ...needs to be between 4 5 from ceiling ii It is recommended to adjust height of legs prior to adding top octagonal frame c FOR RETROTEC FANS i Slide Retrotec fan in between the 4 legs See pictures below...

Страница 6: ...completely or test may yield inaccurate results 4 Ensure hood is flush by lightly pushing up on bottom of hood a If you see the top of hood move readjust poles by going higher b Check again and repeat...

Страница 7: ...Gauge 1 Take the pressure tap coming out the bottom of the flow hood and connect it to the input tap to read pressure 2 See page 9 for complete connection details Complete WHF PFH with TEC Model 3 Fa...

Страница 8: ...procedures 1 Open the window s that are typically opened during WHF operation 2 Turn on all WHFs required to meet the dwelling unit WHF airflow rate Adjust multiple or variable speed WHFs to operate...

Страница 9: ...he channel A pressure channel reference tap open to read pressure inside the dwelling 5 On TEC Model 3 fan connect the pressure tap from the blower door fan to the channel B flow channel input tap 6 O...

Страница 10: ...e airflow Verify all tube connections are properly connected for airflow measurement apparatus and hood adapter system Ensure proper connection of the WHF PFH flow hood to testing fan apparatus has a...

Страница 11: ...ow rate listed on CF 1R report Title 24 reports that have modeled medium speeds for 2019 code only need to be tested at medium speed If the measured flow rate is failing too low try running WHF at a h...

Страница 12: ...12 Rev 6 11 20 MAKERS OF THE QUIETCOOL ADVANCED WHOLE HOUSE FAN...