background image

QUIETCOOLSYSTEMS.COM

12

2-6  Installing the Wall Switch 

1. 

Using your hands, slide the Wall Switch off 
the mounting plate. 

2. 

If you have an existing Wall Switch with a 
junction box installed, install the mounting 
plate over the junction box using the oblong 
holes on the mounting plate. Make sure you 
install the mounting plate with the arrow 
facing upwards. 

3. 

If you do not have an existing junction box, 
simply install the mounting plate to the 
drywall. Using the included drywall anchors 
and screws, mount the plate onto the 
drywall through the four mounting holes. 
 

3. OPERATION 

3-1 

Operating the Wall Switch

 

Timer Button

• 

The top button on the switch controls the Timer 
functionality of the fan.

• 

This button must be pressed for the fan to turn 
on.

• 

Button Presses:

Speed Button

• 

The bottom button on the switch controls the speed functionality of the fan. 
 
 
 

1   2   4   8  12

H

M

L

1   2   4   8  12

H

M

L

One Press:

 1 Hour

Two Presses:

 2 Hour

Three Presses:

 4 Hours

Four Presses:

 8 Hours

Five Presses:

 12 Hours

Six Presses:

 Continuous On

Seven Presses:

 Off

One Speed Fan

•  First press: ON

Two Speed Fan

•  First press: HIGH
•  Second press: LOW

Three Speed Fan

•  First press: HIGH
•  Second press: MED
•  Third press: Low

Содержание IT-36002

Страница 1: ...QUIETCOOLSYSTEMS COM 1 SEE HEAR FEEL THE QUIETCOOL DIFFERENCE ADVANCED WHOLE HOUSE FANS OWNER S GUIDE RF WIRELESS CONTROL...

Страница 2: ...nly qualified service personnel should service the QuietCool system The user should not attempt to service the product CONTENTS 1 SYSTEM OVERVIEW 3 1 1 Introduction 3 1 2 Features 3 1 3 Key Specificat...

Страница 3: ...ate the equipment 1 SYSTEM OVERVIEW 1 1 INTRODUCTION Congratulations on the purchase of your new QuietCool RF Wireless Control The QuietCool Whole House Fan RF Wireless Control is the simplest way to...

Страница 4: ...torhead 4 Using your philips screwdriver open up the Hub and install the powercord bushing through the hole at the back of the hub 5 Run the motor wire leads through the large knockout in the bottom o...

Страница 5: ...shown in the diagram below 7 Power on the Hub The Power LED indicator will be lit 8 Press the Test button to make sure the fan works The Test LED indicator will blink once every two seconds indicating...

Страница 6: ...shown in the diagram below 8 Power on the Hub The Power LED indicator will be lit 9 Press the Test button to make sure the fan works The Test LED indicator will blink twice every two seconds indicati...

Страница 7: ...Hub as shown in the diagram below 8 Power on the Hub The Power LED indicator will be lit 9 Press the Test button to make sure the fan works The Test LED indicator will blink twice every two seconds i...

Страница 8: ...inside the Hub as shown in the diagram below 8 Power on the Hub The Power LED indicator will be lit 9 Press the Test button to make sure the fan works The Test LED indicator will blink twice every tw...

Страница 9: ...diagram below 8 Power on the Hub The Power LED indicator will be lit 9 Press the Test button to make sure the fan works The Test LED indicator will blink three times every two seconds indicating 3 sp...

Страница 10: ...l light up as shown below when the Test button is pressed and when the fan is turned on via the Wall Switch 1 One Speed Fan blink once every 2 seconds 2 Two Speed Fan blink twice every 2 seconds 3 Thr...

Страница 11: ...cating successful pairing Press the Wall Switch button again the speed indicators will go out and it will display the current fan status 6 Press the Timer button to test the Wall Switch to make sure i...

Страница 12: ...and screws mount the plate onto the drywall through the four mounting holes 3 OPERATION 3 1 Operating the Wall Switch Timer Button The top button on the switch controls the Timer functionality of the...

Страница 13: ...ndicators are on and only one of the Speed LED indicators are on the fan is running in Continuous On mode at the indicated speed level The fan will continue to run until you press the Timer button to...

Страница 14: ...e not in the correct position Disconnect power adjust your DIP switches and the only light that should be lit is your RED power light Why is there a medium speed if my fan is only a two speed The RF H...

Страница 15: ...un install any components 3 Product failure or damage due to faulty installation abuse misuse unauthorized alteration to factory specs lack of maintenance or transportation damage 4 Shipping or postag...

Страница 16: ...1 888 QUIETCOOL 16 ADVANCED WHOLE HOUSE FANS 43352 Business Park Drive Temecula CA 92590 PH 951 325 6340 QUIETCOOLSYSTEMS COM QuietCool is Proudly Designed and Built in California...