INSTRUCTIONS

 

 
The red lead: remove the protective inserts from the ends. Connect one end to the red 
socket in the end of the probe. Connect the other end to one of the red (+) sockets on 
the tester, it doesn’t matter which one. 
 
The black lead with the crocodile clip is for testing item

s that don’t fit on the test plate 

easily, see 

TESTING LARGE ITEM 

on the next page. Most items fit on the test plate 

so you will rarely need the black lead.  
 
Press the 

ON/OFF 

button so that it locks down. The needle should move to the far 

right of the grey-

shaded area marked ‘P’ (P is for Platinum).  Every test must start 

with the needle in this position, a lower position indicates a low battery (see 

CHANGING THE BATTERY

 on the next page). 

 
Remove the protective snap-cap from the probe.  
 
Place the calibration sample on the test plate and ensure that the it is making firm 
contact (if it is not, you must hold it down with your finger).  Place the probe tip 

gently

 

on the 18ct sample and wait for the needle to move settle in the 18ct (white) area. 
This will take 2 to 5 seconds.  Without moving the probe, adjust the calibration knob 
until the needle is in the exact centre of the 18ct (white) area. Remove the probe tip, 
carry out the test again (this time the needle will settle more quickly) to be certain it 
calibrated correctly.  If you are not certain, carry out the test a third time. 
 
For standard testing of jewellery, this method of calibration is accurate enough. For 
testing 20ct to 24ct see 

TESTING HIGH-CARAT ACCURATELY 

on the next page. 

 
Now that the tester is calibrated, test your unknown samples in exactly the same 
way, 

except

 that you must file the area to be tested (where you will place the probe 

tip) with the steel file, to ensure you remove any gold plating. 

There is no gold 

jewellery tester that can test through plating!

  Once you are certain the item is not 

plated, further tests may be carried out without filing, just use the abrasive tip to 
ensure it is perfectly clean.  
 
Check the reading against the 18ct calibration sample whenever you turn the tester 
on. If you test large batches of items, check it every dozen tests (keep the calibration 
sample on the test plate). If, at any time, it does not read 18ct, calibrate it.  
 
When you have finished testing, replace the snap-cap firmly or the probe will dry out 
(or salt crystals will start to form around the tip). 

The probe is not guaranteed, if it 

dries out, you’ll have to buy another

 so please take great care to replace the cap 

firmly after use. We strongly suggest you keep a spare probe in stock. 
 

Содержание KEE M-509GM

Страница 1: ...LECTRONIC GOLD TESTER MODEL M 509GM www quicktest co uk All equipment must be used in conjunction with the user s skill knowledge and experience Under no circumstances shall Quicktest be liable for direct or indirect loss sustained in connection with testing equipment It is your responsibility to regularly check readings against known samples ...

Страница 2: ... samples on the test plate and then touch the top of the sample with the probe tip Is it necessary to clean the side of the sample that is resting on the test plate If it is covered with a layer of dirt then yes otherwise no there is no need to clean it you may if you wish but it s not necessary The item must make firm contact with the plate if it does not have a flat surface that makes firm conta...

Страница 3: ...use either F Black socket on tester G Abrasive tip H Protective snap cap on probe I Probe tip J Replaceable part of probe K The end of the probe with the red socket L The red socket on the end of the probe M The red plug on the red lead they are both the same N The black plug on the black lead O Crocodile clip ...

Страница 4: ...rea Remove the probe tip carry out the test again this time the needle will settle more quickly to be certain it calibrated correctly If you are not certain carry out the test a third time For standard testing of jewellery this method of calibration is accurate enough For testing 20ct to 24ct see TESTING HIGH CARAT ACCURATELY on the next page Now that the tester is calibrated test your unknown sam...

Страница 5: ...ld be about 22ct you may wish to know if it is slightly more or slightly less than 22ct Calibrate the tester on your 18ct calibration sample then calibrate it on a 22ct sample You might easily calibrate them both to the middle of the 18ct and 22ct area of the dial or you might have to compromise by setting one or both of the samples fractionally higher or lower This is fiddly but it is the only wa...

Страница 6: ...W ON THE DIAL It takes one AA battery Use a good quality alkaline or Lithium battery The outer sleeve is made of a soft rubber it simply pushes off as shown in the photographs below Then remove the two screws open the tester replace the battery ...

Страница 7: ...e gets used up you will have to calibrate it more often Eventually you will have to calibrate it every few tests this is a sign that the probe refill will soon need replacing What if the meter doesn t move to the far right upon start up Change the battery What if it won t calibrate to the middle of 18kt First change the battery If that doesn t work change the probe refill Can more than one item be...

Отзывы: