Quicklynks BA1000 Скачать руководство пользователя страница 7

LEAGEND

                                                                                                                                                                Battery Tester    BA1000 User Manual 

BA1000 

Tester will display the following contents in a sequence, select accordingly.     

 

3.1 Battery test   

 

 

 

 

Now  the  tester  detects  the  surface  charge  has  been  eliminated,  turn  lights  off  as  prompted,  then  press  OK  key.  The  tester  will  recover 

automatic test 

Select Battery Type 

After the battery charge status selected, tester will prompt to select battery type, i.e. Regular Flooded, AGM Flat Plate or 
AGM Spiral, Gel and EFB battery. Press UP/DOWN key to select battery type, then press OK key to confirm 
 
 
 
 
 
 
 
 
 

Battery System Standard and Rating 

BA1000 battery tester will test each battery according to the selected system and rating. 

Use  UP/DOWN  key  to  select  according  to  the  actual  system  standard  and  rating  marked  on  the  battery.  Use  UP/DOWN  key  to  select 

according to the actual system standard and rating marked on the battery. See in the below picture, the arrow indicated location.   

 

CCA: Cold Cranking Amps, specified by SAE&BCI, most frequently used value for starting battery at 0°F (-18°C). 

BCI:   Battery Council International standard 

CA

 Cranking Amps standard, effective starting current value at 0°C   

MCA: Marine Cranking Amps standard, effective starting current value at 0°C. 

JIS

 Japan Industrial Standard, displayed on the battery as combination of the numbers and letters, e.g. 55D23,80D26. 

DIN

German Auto Industry Committee Standard 

IEC

Internal Electro technical Commission Standard   

EN

  European Automobile Industry Association Standard   

SAE: Society of Automotive Engineers Standard     

GB

 China National Standard 

1.Battery Test 

2.Cranking Test 

3.Charging Test 

4.Review Data 

5. Print Data 

6.System Setup 

Main Menu 

1.Regular Flooded. 

2. AGM Flat Plate. 

3.AGM spiral 

4.GEL 

5.EFB 

Battery Type 

Содержание BA1000

Страница 1: ...Item BA1000 ...

Страница 2: ...st is mainly targeted to analyze the battery Health status to calculate the actual cold cranking capability of the battery and the aging extent which provide reliable analysis evidence for the test and maintenance of the battery It notifies the user to replace battery in advance when the battery getting aged Cranking test is mainly to test and analyze the starting motor Through testing the actual ...

Страница 3: ...nt Requirement Working Environment Temp 20 C 60 C It is applicable for automotive manufacturers automotive maintenance and repair workshops automotive battery factories automotive battery distributors and educational organizations etc 2 PRODUCT INFORMATION 1 2 4 3 5 6 7 8 9 ...

Страница 4: ...inter Choose the function of PRINT DATA and confirm it then print the testing result 8 Battery Clips Connect to the Positive and negative electrodes of auto battery 9 Mini USB Socket in the side of the product Connect to computer for print via USB cable 2 2 Product Specifications 1 Display large 128 64 easy to read LCD backlit 2 Operating Temperature 0 to 50 C 32 to 122 F 3 Storage Temperature 20 ...

Страница 5: ...urn to previous menu Fn Setting 2 From Tool Setup menu use OK button to select 2 Use UP and DOWN button to select the desired language and press OK button to save your selection and return to previous menu Contrast 1 From Tool Setup menu use OK button to select contrast 2 Use UP and DOWN button to select the contrast value and press OK button to save your selection and return to previous menu 38 C...

Страница 6: ... 3 Operation and Test After connect the tool to vehicle battery tester displays the tester model version and batter voltage 3 0 FN key There is One Click Key to test the battery status as setting 1 Voltmeter 2 Battery Test as last testing setting 3 More Software Version 1 00 Hardware Version 1 00 Tool Information Auto battery tester BA1000 Version 1 0 Voltmeter 12 40V ...

Страница 7: ...attery Use UP DOWN key to select according to the actual system standard and rating marked on the battery See in the below picture the arrow indicated location CCA Cold Cranking Amps specified by SAE BCI most frequently used value for starting battery at 0 F 18 C BCI Battery Council International standard CA Cranking Amps standard effective starting current value at 0 C MCA Marine Cranking Amps st...

Страница 8: ...nput correct test standard and rating press OK key tester starts to test and dynamic interface TESTING prompted See below It takes around 3 seconds to display the battery test result Battery Test Result Battery test result includes 5 types as following 1 Good Battery The battery is without any problem please be relaxed to use CCA Select Input 500 CCA Setting Rate Health 96 490CCA Charge 98 12 64V ...

Страница 9: ...r If same test result appears after recharge and retest the battery is regarded as damaged replace the battery 3 2 Cranking Test Tester prompts as following Starting the engine as prompted tester will automatically complete the cranking test and display the result Start Engine Cranking Test RPM Detected Cranking Test Health 78 440CCA Charge 30 12 20V Internal R 7 2mΩ Rated 500A GOOD RECHARGE Healt...

Страница 10: ...e accuracy of the test result Tester will do the following tests in a sequence Loaded Volt Test takes approx 3 seconds then it hints Step on accelerator to increase engine rotating speed Operate accordingly to increase the engine rotating speed to 2500turns or above and keep for 5 seconds Tester starts the charging volt test after increase rev detected After the test finished tester displays the e...

Страница 11: ...he normal high volt of the voltage regulator is maximum 14 7 0 5V If charging volt is too high it will overcharge the battery Therefore the battery life will be shortened and troubles will be caused 4 No Volt Output No generator volt output is detected Check the generator connection cable and the belt whether they are normal 5 Diode Test Through the test of charging current ripple tester will find...

Страница 12: ...s not apply to damages caused by improper use accident flood lightning or if the product was altered or repaired by anyone other than the Manufacturer s Service COK 3 We shall not be liable for any incidental or consequential damages arising from the use misuse or mounting of the Scan Tool Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not a...