LEAGEND
Battery Tester BA1000 User Manual
10
BA1000
Check the connection between generator and battery, then retest.
Charging Test Result:
1) Charging Volt: Normal
Charging system shows the generator output normal, no problem detected.
2) Charging Volt: Low
Charging volt of the charging system is low.
Check drive belt of the generator whether slip or running off. Check the connection between generator and battery is normal or not.
If both of the drive belt and the connection are in good condition, follow the manufacturer's suggestion to eliminate generator fault.
3) Charging Volt: High
Generator output volt is high.
Since most of the vehicle generators are using internal regulator, the generator assembly has to be replaced.(Some old style cars are using
external regulator, then directly replace the regulator.)
The normal high volt of the voltage regulator is maximum 14.7±0.5V.If charging volt is too high, it will overcharge the battery. Therefore the
battery life will be shortened and troubles will be caused.
4) No Volt Output:
No generator volt output is detected. Check the generator connection cable and the belt whether they are normal.
5) Diode Test:
Through the test of charging current ripple, tester will find out whether the diode is normal or not. When ripple volt is too high, it proves at
least one diode is damaged. Check and replace the diode.
Till now, all tests have been done.
3.4 Review Data
Choose the function of Review Data
Check the history of battery testing result
3.5 Print Data
1. Choose the function of Print Data and press OK.
1.Battery Test
2.Cranking Test
3.Charging Test
4.Review Data
5. Print Data
6.System Setup
Main Menu
1.Battery Test
2.Cranking Test
3.Charging Test
4.Review Data
5. Print Data
6.System Setup
Main Menu
Health:96% 490CCA
Charge:98% 12.64V
Internal R=6.1m
Ω
Rated: 500A
GOOD BATTERY