The horn button:
The horn will sound while this button is depressed.
Speed / Profile decrease button:
This button decreases the maximum speed setting or, if the
control system is programmed for drive profile operation,
selects a lower drive profile.
Speed / Profile increase button:
This button increases the maximum speed setting or, if the
control system is programmed for drive profile operation,
selects a higher drive profile.
Actuator button and LEDs:
Depending on whether your wheelchair is fitted with one or
two actuators the operation of these buttons will differ.
Wheelchairs with one actuator
Depressing either actuator button will enter actuator
adjustment mode. This will be indicated by the illumination
of both actuator LED’s. Actuator adjustment can then be
made by deflecting the joystick forwards or backwards. To
re enter drive mode, depress either actuator button
Wheelchairs with two actuators
Depressing either actuator button will enter actuator
adjustment mode.
If the left button is depressed the associated LED will be
illuminated, and deflection of the joystick will adjust the
actuator motor connected to that channel.
If the right button is depressed the associated LED will be
illuminated, and deflection of the joystick will adjust the
actuator motor connected to the other channel.
To re enter drive mode, depress the selected actuator
button, as indicated by the associated LED
It is also possible to select the other actuator by left or right
movements of the joystick
R-net Control
Please refer to your R-net Owner’s Manual for
details.
Charging and programming socket:
WARNING!
This socket should only be used for programming and
charging the wheelchair.
WARNING!
This socket should not be used as a power supply for any
other device. Connection of other electrical devices may
damage the control system or affect the EMC performance
of the wheelchair
See section 11 about charging.
The programming socket will enable an approved Sunrise
Medical authorised dealer to re-programme your chair
and also gain useful information when tracing any faults.
When the chair leaves the factory, the parameters of the
controller are set to default.
To programme the controller you need a special
programming device (handheld or PC software), which is
available through your Sunrise Medical authorised dealer.
WARNING!
Programming the controller of the wheelchair is only allowed
through authorised personnel trained by Sunrise Medical.
Incorrect controller settings could cause driving outside the
safe limits and could result in damage or injury.
WARNING!
SUNRISE MEDICAL does not accept responsibility for
damages which result from unexpected stopping of the
wheelchair or inappropriate programming or unauthorised
use of the wheelchair.
R-net Control
Please refer to your R-net Owner’s Manual for
details.