Ⅶ
.Calibrating the Temperature
The soldering iron should be calibrated after changing the iron. The unit adopts
digital calibration mode and the revision value is inputted by pressing button, make
the adjustment easily.
Calibrate by using thermometer:
1.
Set the unit’s temperature to a certain value.
2.
When the temperature stabilizes, measure the tip’s temperature with
thermometer and write down the reading.
3. Press “1” and “3” button not loosen, the soldering station enters into
calibrating temperature mode and LCD display flash, press “+” or “
—
” key
change temperature value, fit with thermometer reading, press ENTER affirm.
We recommend using the 191/192 thermometer for measuring the tip
temperature.
If the soldering station is locked by password, it will not be able to
calibrate the tip temperature and you must input the right password.
. Specifications
Ⅳ
Type
TS2200
Temperature displaying type
LCD
Power consumption
90W
Working voltage
220VAC
Temperature Range
100
℃
~480
℃
/212F~896F
Temperature Stability
±2
℃
Ambient Temperature(Max)
40
℃
Tip to Ground Resistance
<
2mV
Tip to Ground Potential
<
2Ω
Dimension (W×H×D)
137
×
114
×
168
mm
Ⅴ
. Setting & Operating the Soldering Station
CAUTION:
Before operation, please check whether the voltage accords with the rated
voltage on the unit’s nameplate.
5.1 Iron Holder and Sponge
CAUTION:
The sponge is compressed. It will swell when moistened with water.
Before using the unit, moisten the sponge with the water and squeeze it
dry. Failure to do so may result in damage to the soldering tip.
If the sponge becomes dry during working, add appropriate water.
1.
Dampen the small cleaning sponge with water and then squeeze it dry.
2.
Place it in groove of the iron holder base.
3.
Add a little water to iron holder. The small sponge will absorb water to keep
the large sponge around it wet at all times.
Dampen the large cleaning sponge and place it on the iron holder base.
Page3