10. Equipment Maintenance
Remark:
For ensuring reliable function and maintenance of equipment, please use parts provided by original
factory.
Please turn off power switch at each part and pull out the power plug when not in use.
Caution:
After cutting off the power supply, please do clean after the surface of the equipment
is still very hot and don’t use any dangerous or combustible solvent to clean it.
10.1 Clean parts
1.
Clean the dust on system with clean towel.
2.
Suggest using dry or wet towel to clean the equipment. Solder on the glass of Bottom Radiator can be cleaned
out with hard object. Please be careful not to break down the glass.
3.
Clean the prism of camera with pledget and be careful not to scrape it.
4.
Use the towel with cleaning oil to clean PCB fixture and orbit.
10.2 Replace Suction Pad
1.
If you want to replace the suction pad, please turn off power, and replace it after the vacuum suction nozzle
and top heater cooling down.
2.
Take the suction pad out of suction nozzle downwards, and install a new one in opposite direction.
Note: QUICK BGA EA-A10 is precise equipment. Please don’t make any changes on it.