37
CHC1103 IT EN FR - REV001A
EN
SYSTEM ERRORS AND FAULTS
SYSTEM ERRORS
System errors may arise when the chain counter is turned on.
Checksum error
The following windows are displayed if the counter detects an error in the memorized data:
CONTROL CHECKSUM
FLASH CHECKSUM
ERROR
TRUE:
XXXX
SUM:
YYYY
CONTROL EEPROM
EEPROM CHECKSUM
ERROR
TRUE:
XXXX
SUM:
YYYY
MULTI MASTER
ERROR
SET VALUE:
SLAVE
MASTER
Select chain counter’s priority in the CAN network
(see chapter MULTIPLE CHAIN COUNTERS).
EEPROM memory
checksum error
FLASH memory
checksum error
If one of these messages appears do not use the chain counter and contact a service center or QUICK
®
customer service
without delay.
Multi Master error
If the chain counter detects more then one of MASTER chain counters in the CAN network, the
following window is displayed:
CAN BUS communication error
This fault is displayed if there are errors that cannot be recovered during CAN network
communication.
Make sure the data cables are properly connected.
No MASTER
This fault is displayed if there is not a chain counter with MASTER priority in the CAN network (see
chapter MULTIPLE CHAIN COUNTERS).
See if the MASTER chain counter is on and the data line connections.
LOW VOLTAGE
35.3
M
SPEED
0M/M
STOP
NO MASTER
35.3
M
SPEED
0M/M
STOP
CAN ERROR
35.3
M
SPEED
0M/M
STOP
SYSTEM FAULTS
System faults that appear on the state line divided into three categories which are shown below: problems with automat-
ic reset, problems with automatic reset and keys locked and problems with manual reset.
PROBLEMS WITH AUTOMATIC RESET
These faults are automatically reset as soon as the cause that had generated the problem disappears.
Low voltage
The fault is displayed if the power supply voltage drops below 10.5Vdc for more than one second.
The reset of this problem occurs if the power supply voltage exceeds the threshold of 11.0Vdc for
more than one second.
Check the charge state of the battery group that supplies power or the electrical plant.
Opposed commands
This fault is displayed if keys UP or DOWN of the chain counter are pressed at the same time as
the respective external control DOWN or UP key (another chain counter or another remote switch).
If the fault is present, keys
p
,
q
(UP, DOWN) are disabled.
PROBLEMS WITH AUTOMATIC RESET AND KEYS LOCKED
These faults are automatically reset as soon as the cause that had generated the problem disappears. Some keys are
disabled when these faults are present.
Remote programming active
This fault is displayed if a chain counter has entered the SETTINGS menu in the CAN network (see
chapter MULTIPLE CHAIN COUNTERS). Wait until the chain counter has exit the menu.
If the fault is present, key
=
(SELECT) is disabled.
OPPOSED
35.3
M
SPEED
0M/M
REMOTE PROG
35.3
M
SPEED
0M/M