BTR
Series
EN
QUICK
BTR Series
INSTALLATION AND USER’S MANUAL - REV 001C
19
6 - Operation
6.0 - Dip-Switch for option selection
SELECTION
FUNCTION
DIP-SWITCH
1
Reserved (always keep off)
ON
1
2 3 4
2
It indicates to the CAN control station that the thruster is in the bow (OFF)
ON
1
2
3 4
It indicates to the CAN control station that the thruster is in the stern (ON)
ON
1
2
3 4
3
Reserved (always keep off)
ON
1 2
3
4
4
Reserved (always keep off)
ON
1 2 3
4
FACTORY SETTING: 1 = OFF, 2 = OFF, 3 = OFF, 4 = OFF
ON
1 2 3 4
6.1 - Actuator current rotary selector
The ten selectable steps (from 0 to 9) allow you to set a percentage referring to the “maximum current/load” allowed for the
actuator in use (see table).
ROTARY SELECTOR
POSITION
MAXIMUM CURRENT/
LOAD %
0
28%
1
36%
2
44%
3
52%
4
60%
5
68%
6
76%
7
84%
8
92%
9
100%
If a setting other than the factory setting is required, proceed as follows:
1) With the board not powered, place the arrow of the rotary selector in the desired position.
2) After powering the board again, the percentage corresponding to the selected position will be automatically set.
If the maximum current/load limit is too low compared to the real needs of use, the thermal cut-outs of the actuator may be
tripped during retractable thruster closing and opening with error 1 and 7 flashing.