BTAC Series
6 - Connection diagram
3
380...690 Vac
F
Use shielded cables to connect the inverter
to the motor.
*this data refer to S3 operating mode (periodic intermittent duty) - for any modification please contact Quick
MOTORE
MODEL
MOTOR
POWER
VOLTAGE
INVERTER
POWER
ABSORPTION ON
GENERATORS*
BT250AC200
15 kW
400 V
15 kW
19 kW
BT300AC300
15 kW
400 V
15 kW
21 kW
BT300AC350
22 kW
400 V
22 kW
27 kW
BT386AC420
30 kW
400 V
37 kW
35 kW
BT386AC460
37 kW
400 V
37 kW
40 kW
BT513AC1000
75 kW
400 V
75 kW
90 kW
7 - Warnings
BTAC series
NOTE:
the bow thruster must be installed with
the RH propeller on the right-hand side of the
gearleg (see figure).
RH
WARNING:
This thruster is not designed for a continuous use. It is equipped with protections which limit its operation at
a maximum time span, as reported on the controls’ manual.
It is strongly forbidden to bypass or modify such protections in order to increase the operating time span, under pain of
voiding the warranty and thus lifting any responsibility from Quick
WARNING:
Make sure no swimmers or floating objects are in the vicinity before switching on the thruster.
WARNING:
There must not be flammable materials in the peak or in the area where the Thruster motor is.
WARNING:
Do not operate the bow thruster out of the water for more than 10 seconds.
WARNING:
During docking, it is recommended not to leave in the water any free rope, which may be sucked in by the propellers,
thus leading them to break.
7.0 - Warnings