QUICK2025 manual operation
* PCB Fixture
●
Movable PCB fixture is able to fix PCB with different size. It has four lock knobs and two micro-adjusting
knobs. Two PCB lock knobs are used for locking PCB Fixed Bar to prevent it from moving the PCB. The
other two Fixture Lock Knob is used for locking orbit to prevent fixture from moving. The two
micro-adjustable knobs are used for precise adjusting when the elements align.
●
Unscrew PCB Lock Knobs and push the Slide Block by hand to open the PCB Fixed Bar, make the distance
accord with PCB size. Fix PCB between them and screw down PCB Lock Knobs after adjusting position.
PCB can move forwards and backwards between Fixed Bars. If you want to lock PCB Fixture, please screw
down Fixture Lock Knobs.
●
when the elements precise align, screw down the lock knobs before micro-adjusting. Turn “micro-adjusting
knob one” for moving the PCB fixture to left or right. The PCB fixture to right when turning clockwise and
to left when turning anticlockwise. Turn “micro-adjusting knob two” for moving the PCB fixture to front or
back. The PCB fixture moves to front when turning clockwise and to back when turning anticlockwise.
Micro-adjusting knob
Lock knob
●
Fixing Anomalistic PCB
Fix anomalistic PCB with anomalistic knightheads and
bottom fixtures for preventing subside.
*
Keyboard Instruction
The keyboard can control all the data setting and modifying flows. The keys in the middle of the keyboard
are used for setting parameters and the keys in the right are used for adjusting the light of the camera and
zooming the image. The keys in the left are function keys to control the start and exit of the process.
Page 10