2) Rear
View
A: Support fastener B: Reset button
C: NO (normally open) D: GND (ground)
E: NC (normally connected) FG: AC / DC
H: Product Label I: Micro SD
Connection instructions:
(NO + GND): to magnetic lock
(NC + GND): to electric lock
AC/DC: to AC 8-16V or DC 9-24V, without polarity difference
Micro SD: installed/removed in power off state, with a maximum of 64G supported.
Reset button
Operation: Long press the reset button for 5 seconds and release to restore the factory