4. Connect the ducting to the fan’s duct collar. Seal ducting with appropriately rated tape. Use suitable 

clamps to secure ducting in place. Make sure the fresh air intake is connected to a properly installed 

intake port that is a suitable weather hood with insect screen to protect air intake. It is recommended that 

low restriction termination fittings be used. 
5. Ensure duct joints and exterior penetrations are sealed with caulk or other similar material to create an 

air-tight path to minimize building heat loss or gain and to reduce the potential for condensation. 

Place/wrap insulation around duct and/or fan in order to minimize possible condensation buildup within 

the duct, as well as building heat loss or gain. 
NOTE:

 

At the base of the inlet duct adapter, there is a small diameter test port hole covered with a 

rubber cap. Make sure the test port is not covered up with the ducting so that it can be accessed for pitot 

tube testing. To access the port, remove the port cover and insert a pitot tube.  

Optional Air Filter 

An air filter (available separately) can be added to this unit to provide additional filtration of the intake air. 

The unit will accept a nominal 10” x 10” x 2” filter.

  

1. Release the toggle latch securing the cover in place and open the cover 
2. Squeeze and remove the spring that secures the insect filter in place. 

3. Slide the filter into the slot in the housing. Make sure the filter is seated to the bottom of the housing. 
4. Squeeze the spring and re-engage the spring, close the cover 

and tighten the toggle latch. 

ELECTRICAL CONNECTIONS

  

1. Remove the screw and place the wiring plate in a secure place. 
2. Run 120 VAC house wiring to the location of the fan. Use only UL-

approved connectors (not included) to attach the house wiring to the 

wiring plate. Refer to the wiring diagram, and connect the wires as 

shown. 
3. Carefully tuck wires back inside wiring plate and replace wiring 

plate securing with the screw that was removed. 

WARRANTY 

QuFresh warrants this product to be free from defects in materials and workmanship for a period of one 

year from the date of purchase. Warranty does not apply to product which fails due to abuse, misuse, 

incorrect installation or improper maintenance. During the one-year warranty period, QuFresh will repair 

or replace, at its option, any product or part which has a factory defect in workmanship or materials. 
The foregoing shall constitute our sole and exclusive warranty and our sole and exclusive liability, and is 

in lieu of any other warranties, whether written, oral, implied or statutory. Under no circumstances will 

QuFresh be liable for incidental or consequential damages occurring in connection with the use or 

performance of the product or other indirect damages with respect to loss of profits, revenue or property 

or cost of removal, installation or reinstallation. 
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and 

some states do not allow limitations on how long an implied warranty lasts, so the above exclusions may 

not apply to you. 
This warranty gives you specific legal rights and you may have other rights which vary from state to state 

and province to province. 

 

 

Содержание QuF100X

Страница 1: ...w the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 To Reduce The Risk Of Fire O...

Страница 2: ...ousing is shown upside down for clarity 3 Confirm the fan is appropriately positioned so the air flow is in the correct direction the damper is on the outlet of the fan and the fan can be easily accessed for cleaning and maintenance 4 The fan can be mounted directly to studs joist blocking using appropriate lag screws not included or suspended from hangar rods not included Use thread locker on thr...

Страница 3: ... close the cover and tighten the toggle latch ELECTRICAL CONNECTIONS 1 Remove the screw and place the wiring plate in a secure place 2 Run 120 VAC house wiring to the location of the fan Use only UL approved connectors not included to attach the house wiring to the wiring plate Refer to the wiring diagram and connect the wires as shown 3 Carefully tuck wires back inside wiring plate and replace wi...

Страница 4: ...mode 1 Low Temperature LT knob This set point establishes the low temperature limit setting Below this setpoint the fan will turn off and the unit will be in sampling mode This setting is adjustable from 32 F 50 F 0 C 13 C factory preset 40 F 4 C 2 High Temperature HT knob This set point establishes the high temperature limit setting Above this set setpoint the fan will turn off and the unit will ...

Отзывы: