Technical Notes

Constant Voltage Distributed 

Speaker Systems Demystified 

In a typical paging and background music 
speaker installation, quantity loudspeakers are 
placed across a single amplifier in a parallel 
wiring configuration (see Fig 1.). 

Each ceiling speaker will contain a small 
transformer and you will notice that the 
connection block near the transformer will 
have a common terminal (C or earth), and a 
number of wattage terminals. 

Connect the wattage setting terminal for the 
desired acoustic output (volume) level you 
need from each individual speaker. 

This will be a 100V setting in Europe and 
most of Asia and 70V in the USA. (See the 
explanation below)

Often some speakers need to be set at 
different volume output levels, and the 
calculations involved in determining the actual 
load impedance at the amplifier’s output 
can be quite involved but there is a simple 
technique for not overloading the amplifier

As for the amplifiers, there are two common 
standards, 100 Volt line in Europe and Asia 
and 70 Volt line on the American continent. 

For the purpose of simple calculations, we will 
use the European standard for this exercise. 

On the rear of a 70/100V amplifier you will 
find an output terminal strip (see Fig 2). This 
terminal strip will contain a number of + 

voltage outputs (70V 100V) and a terminal at 
one end for the negative return wire (COM). 

A low impedance terminal will be for 
8-ohm speaker installations and is under 
no circumstances to be connected to a 
transformer type speaker system.

Installation practice 

Step 1 .

 Take a piece of figure-8 cable, 

connect the stripe/coloured wire to the 100V 
terminal and the uncoloured wire to the COM 
on the amplifier terminal strip. 

Step 2 .

 Connect the other end of the wire 

(uncoloured) to the Com/EARTH connection 
on the ceiling speaker transformer and the 
other + (strip) wire to the required voltage 
taping. 

Step 3 .

 Take a second piece of figure-8 cable 

and connect the plain wire to the parallel COM 
connection and the other + (stripe) wire to the 
parallel output from the transformer terminal 
block and connect it in the same way to the 
next ceiling speaker.

Step 4 .

 Continue this process until all the 

ceiling speakers are connected in a parallel 
connection with all the COM connections 
and all the wattage connections following a 
parallel connection. 

Common problems with ceiling 

speaker installations

System is distorting. Check for the following 
causes:

1. Too many speakers set to too high a power 

tapping for the power of the amplifier 

Solution:

 Calculate the total power 

draw and re connect the speakers to a 
lower the wattage tapping. (See below)

  Some cheap ceiling speakers have 

incorrect taping labels. A 10 watt speaker 
may really be drawing 15 or 20 watts. 
The only way to test this is with an 
impedance meter on a single speaker. A 

100V Line Public Address System

Remote Speaker 

with 100V Line 

Transformers

Fig. 1

Содержание QTA 6060M

Страница 1: ...Q Tech Q Tech Commercial Series QTA 6060M 6120M 6250M Mixer Amplifiers User Manual...

Страница 2: ...ts Safety Precautions 1 General Description 4 Features 4 Front Panel Layout 5 Rear Panel Layout 6 Connections 10 Applications 11 Block Diagram 14 Specifications 15 Dimensional Diagram 16 Technical Not...

Страница 3: ...afety Symbol and Message Conventions Safety symbols described below are used in this manual to prevent bodily injury and property damage which could result from mishandling Before operating your produ...

Страница 4: ...op metallic objects or flammable materials in the ventilation slots of the unit s cover as this may result in fire or electric shock When Installing the Unit Do not expose the unit to rain or an envir...

Страница 5: ...is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause...

Страница 6: ...ridge in out feature to allow combining of multiple amplifiers in applications without the need for external relays VCA remote level control circuitry is included which may be assigned to the backgrou...

Страница 7: ...e of 5dB 4 Treble Control The TREBLE CONTROL is a shelving type control which will boost or cut treble frequencies at 10kHz at the rate of 5dB 5 Master Gain Control The MASTER GAIN CONTROL will raise...

Страница 8: ...recording devices The signal available here is PRE tone control and low cut filter and comes from the internal mix bus 15 Line Out A B The LINE OUT connector is useful for providing unbalanced line l...

Страница 9: ...here a lower amplitude signal will trigger a mute send Careful calibration of this control may be required to fully utilize the mute circuits capabilities Adjustment of this control should occur after...

Страница 10: ...its signal from INPUT 6 volume control 25 VCA Remote location of the level control can be accomplished via the VCA control port You can control the overall level Master or just Input 6 This selection...

Страница 11: ...ain installations have the need to combine one or more Mixer amps together These Mixer amps may operate different rooms of an install but have the need to share a page or music throughout the installa...

Страница 12: ...ca Potentiom eter Quest part number VCC 10K consists of a single gang wall plate with a pre mounted 10K poten tiometer and knob This pot may be mounted on a plate to match the wall plates as nominated...

Страница 13: ...ic position Note The INPUT 1 Trim and Sens will need to be adjusted after all the settings and connections have been set Dipswitch Settings Dipswitch 1 Off Set To The Required Gain Dipswitch 2 Off Not...

Страница 14: ...t makes combines or breaks separates the Bridge connections between the amplifiers When the switch is closed any audio signal into either amp will be present at both amplifiers speaker outputs A volum...

Страница 15: ...D player s audio outputs are connected to Input 6 and a recording device cassette recorder or computer s audio input is connected to the Tape Out jacks For system tuning a 1 3rd octave graphic EQ is c...

Страница 16: ...QTA 6000 Series User Manual User Manual Q Tech Commercial Series QTA 6060M 6120M 6250M 14 Block Diagram...

Страница 17: ...mer Mic 316mV 3 16mV 50dBV 70dBV Input 1 5 Line 316mV 10dBV 10Kohm Mic 316mV 3 16mV 50dBV 70dBV Input 6 Line 300mV 100mV 10dBV 20dBV Selectable Outputs Main Transformer coupled balanced 8 25V and 70V...

Страница 18: ...User Manual Q Tech Commercial Series QTA 6060M 6120M 6250M 16 Dimensional Diagram UNIT mm UNIT mm Keep all the unit s sides over 10cm away from objects that may obstruct air flow to prevent the unit s...

Страница 19: ...100V and a terminal at one end for the negative return wire COM A low impedance terminal will be for 8 ohm speaker installations and is under no circumstances to be connected to a transformer type spe...

Страница 20: ...0 The reason is that most ceiling speakers draw more than their claimed wattage The alternative would be to connect the speakers to the 4 watt transformer terminal giving you a theoretical total draw...

Страница 21: ...nce 0 1W 100K 10W 1K 40W 250 0 5W 20K 15W 667 50W 200 1W 10K 20W 500 75W 133 2W 5K 25W 400 100W 100 3W 3 33K 30W 333 150W 66 7 5W 2K 35W 286 200W 50 100V plan P E x E Z 100x100 Z 10 000 Z P Power W Z...

Страница 22: ...QTA 6000 Series User Manual User Manual Q Tech Commercial Series QTA 6060M 6120M 6250M 20...

Страница 23: ......

Страница 24: ...www questaudio net Quest Engineering Pty Ltd 86 Derby St Pascoe Vale VIC 3055 Ph 613 9354 9133 Fax 613 9354 9233...

Отзывы: