background image

1-866-933-7486 

13

www.QuestOnTheJob.com

[email protected]

Quest Dry RDS 10 

Installation, Operation and Maintenance Instructions

  

quest

quest

Quest Dry RDS 10              Installation, Operation and Maintenance Instructions

  

Quest Dry RDS 10 Limited Warranty 

Warrantor:

Therma-Stor LLC 
4201 Lien Rd 
Madison, WI 53704 
Telephone: 1-866-933-7486

Who Is Covered: This warranty extends only to the original end-user of the Quest Dry RDS 10 
dehumidifier, and may not be assigned or transferred.

Year One: Therma-Stor LLC warrants that, for one (1) year the Quest Dry RDS 10 dehumidifier will operate 
free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, repair or replace 
the defective part(s), free of any charge.

Year(s) Two Through Five: Therma-Stor LLC further warrants that for a period of five (5) years, the condenser, 
evaporator, and compressor of the Quest Dry RDS 10 dehumidifier will operate free of any defects in 
material or workmanship, or Therma-Stor LLC, at its option, will repair or replace the defective part(s), 
provided that all labor and transportation charges for the part(s) shall be borne by the end-user.

Year(s) One Through Seven: Materials and workmanship of the housing are covered.

End-User Responsibilities: Warranty service must be performed by a Servicer authorized by Therma-Stor 
LLC. If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he should 
call Therma-Stor LLC at the above number and ask for the Therma-Stor Service Department, which will then 
arrange for covered warranty service. Warranty service will be performed during normal working hours.

The end-user must present proof of purchase (lease) upon request, by use of the warranty card or other 
reasonable and reliable means. The end-user is responsible for normal care. This warranty does not cover any 
defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, 
modification, unauthorized or improper repair or installation, accident, acts of nature or any other cause 

beyond Therma-Stor LLC’s reasonable control.

Limitation and Exclusions: If any Quest Dry RDS 10 Dehumidifier part is repaired or replaced, the new part 
shall be warranted for only the remainder of the original warranty period applicable thereto (but all warranty 
periods will be extended by the period of time, if any, that the Quest Dry RDS 10 Dehumidifier is out of 
service while awaiting covered warranty service).

UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Quest Cool ACS 12 OR 
ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY 
AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY 
THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST THERMA-STOR 
LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR LLC, IN CONNECTION 

WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY Quest Cool ACS 12 OR PART 

THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL 

DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER SHOULD TAKE 

PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY REAL 

OR PERSONAL PROPERTY.

Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the 
exclusion or limitation of incidental or consequential damages, so one or both of these limitations may not 
apply to you. 

Legal Rights: This warranty gives you specific legal rights, and you may also have other rights which vary 

from state to state.

Содержание Dry RDS 10

Страница 1: ...built around tested engineering principles and has passed a thorough inspection for quality of workmanship and function 4201 Lien Rd Phone 608 237 8400 Madison WI 53704 Toll Free 1 866 933 7476 www Q...

Страница 2: ...3 Operation 4 3 1 Transporting 4 3 2 Electrical Requirements 5 3 3 Condensate Removal 5 3 4 Ducting 5 3 6 POWER Button 5 3 7 PURGE Button 5 3 8 Hour Meter 6 3 9 HOURS Button 6 3 10 DEFROST Light 6 4...

Страница 3: ...power cord If the power cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified person in order to avoid a hazard The unit shall be installed in accordance wi...

Страница 4: ...th year 100 of Parts of sealed refrigeration system Dimensions Width 20 Depth 20 Height 33 Weight 105 lbs Patent 7 246 503 3 Operation Place dehumidifier inside structure place condensate hose into a...

Страница 5: ...y then be quickly attached to the Quest Dry RDS 10 by snapping the collar over the four exhaust tabs 3 5 Defrost Cycle If the low side refrigerant temperature drops due to excessive frost formation on...

Страница 6: ...acity and efficiency and may cause the compressor to cycle off and on unnecessarily The filter can generally be vacuumed clean several times before needing replacement Replacement filters can be order...

Страница 7: ...hen passes through a filter drier and capillary tubing which cause the refrigerant pressure and temperature to drop It next enters the evaporator coil where it absorbs heat from the incoming air and e...

Страница 8: ...sed check pump reservoir 3 Defective compressor capacitor 4 Defective compressor overload 5 Defective compressor 6 Defective control board Air mover does not run Compressor runs briefly but cycles on...

Страница 9: ...The motorized impeller has a PSC motor and internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug power cord 2 Remove the four screws attaching the bottom pl...

Страница 10: ...te reservoir The float safety switch turns off the compressor until the water level lowers and disengages the switch To replace the float safety switch 1 Unplug the dehumidifier 2 Remove the front hou...

Страница 11: ...st Dry RDS 10 Installation Operation and Maintenance Instructions quest quest BLU 14 RED 13 COMPRESSOR BLOWER MOTOR LEVEL SWITCH CONTROL BOARD THERMISTOR CONDENSATE PUMP WHT 10 GRN BLK WHT 2 YEL 9 YEL...

Страница 12: ...Wheel 2 4027138 10 Filter 12 x 12 x 1 1 4026315 11 Hose 1 4 ID x 33 long 1 4024916 12 Coupling Body 1 4 Tube 1 4026306 13 Coupling Insert 1 4 Tube 1 4026986 14 Cord 1 4032297 15 Control Board 1 402676...

Страница 13: ...on request by use of the warranty card or other reasonable and reliable means The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse...

Отзывы: