1. Safety Information

•  Do not operate the unit with a cut or frayed power cord. Replace cord if it becomes damaged.
•  Do not unplug the unit by pulling on the cord. Grasp the plug firmly and pull it out of the wall socket or 

power receptacle.

•  Always use a grounded outlet.
•  Never operate electrical equipment in standing water.
•  Never operate with the safety grills removed. Personal injury may result.
•  Do not stick your fingers or other objects through the safety grills.
•  Do not restrict airflow to the unit. This may cause the unit to overheat.
•  Unit should never be serviced or cleaned while it is plugged in.
•  Do not sit or stand on the unit or use as a shelf or table.
•  Before leaving an Axial Air Mover unattended, ensure children do not have access to the equipment. Do 

not allow children to play with or near the unit or in its air flow.

•  To reduce the risk of fire or electric shock, do not use this air mover with any solid-state speed control 

device.

•  Do not route cord under furniture or appliances.

LIRE ET CONSERVER CES INSTRUCTIONS

•  Risque de choc électrique Peut causer des blessures ou la mort. Débrancher toutes les alimentations en 

courant électrique à distance avant l’entretien ou le nettoyage.

•  Ne pas utiliser l’appareil avec un cordon d’alimentation coupé ou effiloché.
•  Ne pas débrancher l’appareil en tirant sur le cordon. Tenir la fiche fermement et la tirer hors de la prise 

murale ou la prise d’alimentation électrique.

•  Toujours utiliser une prise mise à la terre.
•  Ne jamais utiliser l’équipement électrique dans de l’eau stagnante.
•  Ne jamais utiliser sans les grilles de protection. Des blessures risquent d’en résulter.
•  Ne pas passer les doigts ou d’autres objets dans les grilles de protection.
•  Ne pas diminuer le débit d’air arrivant jusqu’à l’appareil. L’appareil risque de trop chauffer.
•  Ne pas s’asseoir ou se tenir debout sur l’appareil; ne pas l’utiliser comme étagère ou table.
•  Avant de laisser un appareil aéraulique axial sans surveillance, s’assurer que les enfants n’ont pas accès 

à l’équipement. Ne pas laisser les enfants jouer avec l’appareil ou à proximité de l’appareil ou dans l’air 

qu’il projette.

•  Pour réduire le risque d’incendie ou de choc électrique, ne pas utiliser ce ventilateur avec un dispositif de 

commande de vitesse à semi-conducteurs.

Содержание A3000

Страница 1: ...rinciples and has passed a thorough inspection for quality of workmanship and function Installation Operation and Maintenance Instructions 4201 Lien Rd Phone 608 237 8400 Madison WI 53704 Toll Free 1 866 933 7486 www QuestProtect com sales QuestProtect com Read and Save These Instructions Specifications subject to change without notice 1 Quest Power Air Mover A3000 Less than 2 5 amps Automatic hou...

Страница 2: ...4 5 Power Requirements 4 5 1 Recommended Use 4 5 2 Integrated Cord Wrap 4 6 Applications 5 6 1 Placement 5 6 2 Orientation of Directional Drying 5 7 Operating Instructions 6 8 Operator Panel Features 6 8 1 3 Position Drying Selector Switch 6 9 Maintenance 6 9 1 Servicing 6 9 2 Cleaning 6 10 Replacement Parts and Optional Accessories 7 11 Wiring Diagram 7 12 Warranty 8 Serial No ___________________...

Страница 3: ... or appliances LIRE ET CONSERVER CES INSTRUCTIONS Risque de choc électrique Peut causer des blessures ou la mort Débrancher toutes les alimentations en courant électrique à distance avant l entretien ou le nettoyage Ne pas utiliser l appareil avec un cordon d alimentation coupé ou effiloché Ne pas débrancher l appareil en tirant sur le cordon Tenir la fiche fermement et la tirer hors de la prise m...

Страница 4: ...late 3 Safety Certifications The Quest Power Air Mover A3000 P N 4028330 conforms to UL STD 507 Certified to CAN CSA STD C22 2 No 113 4 Specifications Part No 4028330 Power 1 4 hp 1 phase 110 120 VAC 2 speed 4 pole PSC Electric Motor CFM Approximately 3000 Cord 20 ft Power Cord Current Draw 2 5 Amps Voltage 115 VAC Warranty Year One 100 parts and labor all components Year Two 100 parts only all co...

Страница 5: ...g air up the wall The best set up angle for quickly and completely drying the sill plate is 4 5 Set up angles greater than 4 5 may be used under unique circumstances such as corner air flow and structure variations Set up angle should never exceed 23 6 2 Orienting of Directional Drying System The Quest Power Air Mover A3000 dries in counter clockwise and clockwise directions for optimum ease of us...

Страница 6: ...H The Quest Power Air Mover A3000 is in Fast drying mode This mode provides the industries most rapid drying while maintaining low noise operation 9 Maintenance WARNING Disconnect the unit from power before servicing or cleaning Replace the wire safety grill after servicing or cleaning 9 1 Servicing Before each use inspect for damage blocked inlet or outlet or any excess buildup of foreign materia...

Страница 7: ...ntact the factory at 1 866 933 7486 to order replacement parts or optional accessories 11 Wiring Diagram Part No Description 4025204 Switch Rocker On Off On 4025206 Grill Safety Intake 4025207 Grill Safety Exhaust 4025460 Quest Power Air Mover A3000 Stand Part No Description 4025299 Stand Hardware Kit 4036823 Motor 4025095 Blade BLK FAN MOTOR RED BLK WHT WHT GRN GRN MAIN POWER CORD LOW 1 HIGH 3 2 ...

Страница 8: ...osion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control If any Quest Power Air Mover A3000 part is repaired or replaced the new part shall be warranted for the balance of original warranty but all warranty periods will be extended by the period of time if any that the Quest Power Ai...