background image

— 3 —

Important Safety Information

Standard safety precautions must always be followed to 
reduce the risk of fire, electric shock, and injury to persons, 
including the following: 
1.  Read these Instructions.
2.   Keep these Instructions.
3.   Heed all Warnings.
4.   Follow all Instructions.
5.   Do not use this apparatus in or near water.
6.   Clean only with a damp cloth.
7.   Do not block any of the ventilation openings. Install in 

accordance with the Manufacturer’s instructions.

8.   Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 
amplifiers) that produce heat.

9.   Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug has 
two blades and a third grounding prong. The wide blade 
or the third prong are provided for your safety. When the 
provided plug does not fit into your outlet, consult an 
electrician for replacement of the obsolete outlet.

10.  Protect the power cord from being walked on or pinched 

particularly at plugs, convenience receptacles, and the 
point where they exit from the apparatus.

11.  Only use attachments/accessories specified by the 

manufacturer.

12.  Use only with a cart, stand, tripod, bracket, 

or table specified by the manufacturer, or 
sold with the apparatus. When a cart is 
used, use caution when moving the cart/
apparatus combination to avoid injury 
from tip-over.

13.  Unplug this apparatus during lightning 

storms or when unused for long periods of time.

14.  Refer all servicing to qualified service personnel. Servicing 

is required when the apparatus has been damaged in any 
way, such as power-supply cord or plug is damaged, liquid 
has been spilled or objects have fallen into the apparatus, 
the apparatus has been exposed to rain or moisture, does 
not operate normally, or has been dropped.

15.  WARNING: To reduce the risk of fire or electric shock, 

do not expose this apparatus to rain or moisture. Do not 
place objects filled with water, such as a vase, on the 
apparatus.

16.  The AC mains plug is used as the power disconnect 

device and it should remain readily accessible and 
operable during intended use. In order to completely 
disconnect the apparatus from power, the mains plug 
should be completely removed from the AC outlet socket.

17.  Keep the cord out of heavy traffic areas. To avoid fire 

hazard, NEVER put the cord under rugs, near heat 
registers, radiators, stoves, or heaters.

18. DO NOT operate any generator with a damaged cord 

or plug, if motor fan fails to rotate, after the generator 
malfunctions, or if it has been dropped or damaged in any 
manner. Return generator to manufacturer or authorized 
repair facility for examination, electrical or mechanical 
adjustment, or repair.

19. Do not  leave the generator in use unattended around 

those requiring close supervision.

20.  WARNING! Always unplug the generator before moving 

it, cleaning, or whenever the generator is not in use. Be 
sure to pull by the plug and not the cord.

21.  This Hydroxyl Generator is for Indoor Use Only.
22.  Do not  attempt to repair or adjust any electrical or 

mechanical functions on this unit other than the UV 
bulbs and Carbon Filters. Doing so will void your 
warranty. All servicing should be performed by qualified 
personnel only.

23.  Do not place anything on top of generator.
24.  Do not  plug the cord in with wet hands: electric shock 

could result.

25.  NEVER use detergents, gasoline, glass cleaner, furniture 

polish, paint thinner or other household solvents to 
clean any part of the generator.

26.  See separate safety instructions (pages 4 and 5) for 

replacing the UV Lamp with mercury. 

27.  For General Ventilating Use Only. Do Not Use to Exhaust 

Hazardous or Explosive Materials and Vapors.

PLEASE READ AND SAVE THESE 

IMPORTANT SAFETY INSTRUCTIONS

Содержание NewAire HG1500

Страница 1: ...fety and maintenance information Keep these instructions for future reference These instructions contain important safety and operating information for your Newaire HG1500 Hydroxyl Generator Please co...

Страница 2: ...ules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause...

Страница 3: ...ain or moisture does not operate normally or has been dropped 15 WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Do not place objects filled with...

Страница 4: ...tip Keep the eyedropper at an angle to stop the mercury from rolling back out until you can put the mercury into the plastic bag Wrap tape sticky side out around your gloved fingers and carefully use...

Страница 5: ...l generator will do the job Hydroxyls are not temperature sensitive and like higher humidity What maintenance is required Very little Simply replace the UV lamps when they burn out see page 9 and repl...

Страница 6: ...6 Location of Controls Power Switch Plastic End Cap Fuse bottom of unit AC Cord bottom of unit Timer Knob Carrying Handle Plastic End Cap...

Страница 7: ...ns THIS APPLIANCE MUST BE GROUNDED In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equip...

Страница 8: ...the new carbon filter then replace the screen and plastic end cap x Re insert the two screws y Repeat for the other carbon filter located on the opposite side IMPORTANT The HG1500 should never be oper...

Страница 9: ...e of the 8 32 screws holding the finger guard in its place and loosen the remaining screw Rotate finger guard 180 so it is out of the way to access the UV Bulb area x Loosen both socket head screws us...

Страница 10: ...fully sliding lamp into lamp holder making sure to align the bottom end of the UV bulb into the bottom recess V Reconnect the power supply then reinsert socket head screws and gently tighten with 5 64...

Страница 11: ...g To clean use a damp soapy cloth for standard cleaning WARNING Make sure the unit is unplugged before maintenance is performed WARNING UV Bulbs MUST be disposed of properly see pages 4 and 5 for deta...

Страница 12: ...Handling and Disposal of Mercury Internal Component failure call 1 866 676 9663 for service Hydroxyl Generator is not performing well The life of the carbon filter may have been met or damaged replace...

Страница 13: ...BE PERFORMED BY AN AUTHORIZED WARRANTY REPAIR CENTER AT THE TIME REQUEST FOR REPAIR IS MADE EVIDENCE OF THE DATE OF PURCHASE AND DATES OF MAINTENANCE WORK MUST BE PROVIDED UPON REQUEST TRANSPORTATION...

Страница 14: ...QUEENAIRE TECHNOLOGIES INC 9483 State Highway 37 Ogdensburg NY 13669 www queenaire com...