GSM/GPRS/GNSS Module Series
MC60-TE-A User Guide
MC60-TE-A_User_Guide Confidential / Released 17 / 25
5.3. Communicate with GNSS Part of the Module
5.3.1. Use Main UART (All-in-one Solution)
(1) Turn the S101 and S102 switch to
ON
state on MC60-TE-A, and then connect the main UART of EVB
to PC’s USB port with the USB to UART converter cable. This is the recommended method.
Figure 10: S101/S102 Switch Status on Main UART When Communicating with GNSS Part
(2) Open the QCOM (AT command window) on PC. Set appropriate Baud Rate (such as 115200bps)
and COM number which can be checked by the Device Manager on PC.
(3) Connect the antenna to the GNSS_ANT on MC60-TE-A with an RF cable.
(4) For power on procedure, please refer to
document [4]
.
(5) After waiting for 2~3 seconds, customers
should first input “AT” or “at” string once or more until
receiving “OK” from the module in the HyperTerminal.
(6) Send corresponding AT commands to power on/off the GNSS part. When GNSS is powered on, the
LED D102 on MC60-TE-A will be lighted and NMEA data will be output. For details of the
corresponding AT commands, please refer to
document [1]
.
5.3.2. Use UART3 (Stand-alone Solution)
(1) Turn the S101 switch to
ON
and S102 switch to
OFF
state on MC60-TE-A, and then connect the
main UART of EVB to PC’s USB port with the USB to UART converter cable.
Quectel