GSM/GPRS Module Series
M85 Hardware Design
M85_Hardware_Design Confidential / Released 72 / 88
GPRS Class 12 is the default setting. The module can be configured from GPRS Class 1 to Class 12.
Setting to lower GPRS class would make it easier to design the power supply for the module.
5.5. Electro-static Discharge
Although the GSM engine is generally protected against Electro-static Discharge (ESD), ESD protection
precautions should still be emphasized. Proper ESD handling and packaging procedures must be applied
throughout the processing, handling and operation of any applications using the module.
GSM850
@power level #5 <350mA, Typical 216mA
@power level #12, Typical 103mA
@power level #19, Typical 83mA
EGSM900
@power level #5 <350mA, Typical 233mA
@power level #12, Typical 104mA
@power level #19, Typical 84mA
DCS1800
@power level #0 <300mA, Typical 171mA
@power level #7, Typical 96mA
@power level #15, Typical 82mA
PCS1900
@power level #0 <300mA, Typical 169mA
@power level #7, Typical 98mA
@power level #15, Typical 83mA
DATA Mode, GPRS (1Rx, 4Tx) CLASS 12
GSM850
@power level #5 <660mA, Typical 457mA
@power level #12, Typical 182mA
@power level #19, Typical 106mA
EGSM900
@power level #5 <660mA, Typical 484mA
@power level #12, Typical 187mA
@power level #19, Typical 109mA
DCS1800
@power level #0 <530mA, Typical 461mA
@power level #7, Typical 149mA
@power level #15, Typical 97mA
PCS1900
@power level #0 <530mA, Typical 439mA
@power level #7, Typical 159mA
@power level #15, Typical 99mA
NOTE