M50 Hardware Design
M50_HD_V2.0
- 76 -
DCS1800/PCS1900
2)
420/470
mA
Peak supply
current
(during
transmission
slot)
Maximum power control level
on GSM850 and GSM900.
1.6
1.8
A
1)
Power control level PCL 5
2)
Power control level PCL 0
5.4. Current consumption
The values of current consumption are shown as below.
Table 37: The module current consumption
Condition
Current Consumption
Voice Call
GSM850
@power level #5 <300mA,Typical 209mA
@power level #12,Typical 96mA
@power level #19,Typical 73mA
GSM900
@power level #5 <300mA,Typical 208mA
@power level #12,Typical 96mA
@power level #19,Typical 73mA
DCS1800
@power level #0 <250mA,Typical 191mA
@power level #7,Typical 93mA
@power level #15,Typical 70mA
PCS1900
@power level #0 <250mA,Typical 202mA
@power level #7,Typical 95mA
@power level #15,Typical 71mA
GPRS Data
DATA mode, GPRS ( 1 Rx,1 Tx ) CLASS 12
GSM850
@power level #5 <350mA,Typical 199mA
@power level #12,Typical 87mA
@power level #19,Typical 63mA
EGSM 900
@power level #5 <350mA,Typical 200mA
@power level #12,Typical 96mA
@power level #19,Typical 70mA
DCS 1800
@power level #0 <300mA,Typical 184mA
@power level #7,Typical 82mA
@power level #15,Typical 66mA
PCS 1900
@power level #0 <300mA,Typical 192mA
@power level #7,Typical 82mA
@power level #15,Typical 66mA
Quecctel
Confidential