LTE Standard Module Series
EG915U-EU_Hardware_Design 33 / 81
3.5. Turn On
3.5.1. Turn on the Module with PWRKEY
Table 9: Pin Definition of PWRKEY
When the module is in power off mode, it can be turned on and enter normal operation mode by driving
the PWRKEY low for at least 2 s. It is recommended to use an open drain/collector driver to control the
PWRKEY.
PWRKEY
4.7K
47K
Turn-on pulse
2 s
10 nF
Figure 9: Reference Circuit of Turing on the Module with Driving Circuit
Another way to control the PWRKEY is by using a button directly. When pressing the button, an
electrostatic strike may generate from finger. Therefore, a TVS component shall be placed near the button
for ESD protection.
PWRKEY
S1
Close to S1
TVS
Figure 10: Reference Circuit of Turing on the Module
with Keystroke
Pin Name
Pin No.
I/O
Description
Comment
PWRKEY
15
DI
Turn on/off the module
VBAT power domain.